Mining
FFr_UNe
Multiconductor - 0.6/1kV - 90ºC - EPR/TPU
Gr/Ye earth conductor

Attributes
Tear and Impacts.
Harsh Environment
Drilling Ring Equipment
Flame-retardant
High Flexibility
Mineral oil resistant
Applications
This type of cable is required for heavy duty industrial use such as drilling equipment and mining in general. It counts with an augmented flexibility and plastic material which provide the right protection against chemical products, harsh environment, tear and impacts.
features
Temperature rating: 90ºC (operating),130ºC (overload) and 250ºC (short circuit).
Voltage rating: 600/1000V AC; 1200V AC / 1500V DC maximum.
Construction requirements: As per IEC 60502-1
Fire requirements: As per IEC 60332-1 - Fire-retardancy.
Conductor requirements: As per IEC 60228 / IRAM NM 280.
These cables comply with the Flexing tests specified in Mercosur standards NM 247-2 for 300000 simple cycles or 150000 double cycles.
description
Conductor: Annealed electrolytic copper; class 5 stranding.
Insulation: EPR
Identification:
- 3 Conductors: | |||||
- 4 Conductors: | |||||
- 5 Conductors: |
Sheath: Polyurethane; black.
installation
Assembly: Minimum bend radius is 7xOD.
Maximum pulling tension: 5daN/sq mm on copper conductors.
Assembly temperature: 5ºC or higher.
Tables
Electrical Characteristics
Nominal cross-section sq mm |
Electrical resistance at 90ºC in AC Ohm/km |
Inductive reactance at 50hz | Current-carrying capacity in free air (1) | Current-carrying capacity in earth (2) |
---|---|---|---|---|
Multiconductor Ohm/km | 3x (3) Ampere | 3x(3)Amper | ||
1 | 24,86 | 0,107 | N/A | N/A |
1.5 | 16,96 | 0,100 | 20,0 | 27,6 |
2.5 | 10,18 | 0,093 | 27,6 | 37,1 |
4 | 6,31 | 0,088 | 36,1 | 48,5 |
6 | 4,21 | 0,083 | 46,6 | 60,8 |
10 | 2,44 | 0,078 | 64,6 | 82,7 |
16 | 1,54 | 0,075 | 86,5 | 107,4 |
25 | 0,995 | 0,075 | 109,3 | 140,6 |
35 | 0,707 | 0,073 | 136,8 | 168,2 |
50 | 0,493 | 0,073 | 166,3 | 198,6 |
70 | 0,348 | 0,071 | 212,8 | 243,2 |
95 | 0,264 | 0,070 | 257,5 | 292,6 |
120 | 0,207 | 0,070 | 299,3 | 333,5 |
150 | 0,166 | 0,070 | 344,9 | 373,4 |
185 | 0,137 | 0,070 | 394,3 | 424,7 |
240 | 0,105 | 0,069 | 464,6 | 493,1 |
300 | 0,0853 | 0,069 | 536,8 | 558,6 |
(1) Cables installed in free air at 40ºC according to IEC 364-5-523.
(2) Cables directly buried in earth at a ground temperature of 25ºC with ground specific thermal resistivity of 1K.m/W.
(3) The values also apply to 4-conductor and 5-conductor cables.
For further information about current-carrying capacity values and types of installations refer to IEC 364-5-523 and the regulations for electrical installations in buildings defined by Argentina's Electrotechnical Association (in Spanish, "Reglamentación para la ejecución de Instalaciones eléctricas en inmuebles", part 7 section 771).
Dimensions & Weight
Conductors per cross-section N° x sq mm | Code | Outside diameter mm | Weight kg/km | Conductors per cross-section N° x sq mm | Code | Outside diameter mm | Weight kg/km |
---|---|---|---|---|---|---|---|
3x1 | FFr 0310 UNe | 10,0 | 109 | 3x50+1x25 | FFr 5025 UNe | 31,9 | 2153 |
3x1,5 | FFr 0315 UNe | 10,7 | 130 | 3x70+1x35 | FFr 7035 UNe | 36,8 | 2967 |
3x2,5 | FFr 0325 UNe | 11,6 | 165 | 3x95+1x50 | FFr 9550 UNe | 42,6 | 3927 |
3x4 | FFr 0340 UNe | 12,6 | 218 | 3x120+1x70 | FFr 12070 UNe | 47,0 | 5008 |
3x6 | FFr 0360 UNe | 14,0 | 288 | 3x150+1x70 | FFr 15070 UNe | 51,9 | 6002 |
3x10 | FFr 3100 UNe | 16,3 | 439 | 3x185+1x95 | FFr 18595 UNe | 57,0 | 7309 |
3x16 | FFr 3160 UNe | 20,9 | 751 | 3x240+1x120 | FFr 240120 UNe | 64,8 | 9605 |
3x25 | FFr 3250 UNe | 24,4 | 1090 | 3x300+1x150 | FFr 300150 UNe | 72,6 | 11884 |
3x35 | FFr 3350 UNe | 26,6 | 1415 | 5x1 | FFr 0510 UNe | 12,4 | 163 |
3x50 | FFr 3500 UNe | 30,4 | 1929 | 5x1,5 | FFr 0515 UNe | 13,2 | 194 |
3x70 | FFr 3700 UNe | 35,6 | 2689 | 5x2,5 | FFr 0525 UNe | 14,4 | 250 |
3x95 | FFr 3950 UNe | 40,9 | 3511 | 5x4 | FFr 0540 UNe | 15,6 | 332 |
3x120 | FFr 31200 UNe | 44,2 | 4356 | 5x6 | FFr 0560 UNe | 17,4 | 443 |
3x150 | FFr 31500 UNe | 50,4 | 5463 | 5x10 | FFr 5100 UNe | 20,2 | 677 |
3x185 | FFr 31850 UNe | 54,7 | 6555 | 5x16 | FFr 5160 UNe | 24,8 | 1093 |
3x240 | FFr 32400 UNe | 62,8 | 8687 | 5x25 | FFr 5250 UNe | 29,1 | 1607 |
3x300 | FFr 33000 UNe | 70,1 | 10738 | 5x35 | FFr 5350 UNe | 32 | 2124 |
4x1 | FFr 0410 UNe | 11,5 | 142 | 5x50 | FFr 5500 UNe | 37,5 | 2974 |
4x1,5 | FFr 0415 UNe | 12,2 | 167 | 5x70 | FFr 5700 UNe | 43,3 | 4089 |
4x2,5 | FFr 0425 UNe | 13,3 | 215 | 5x95 | FFr 5950 UNe | 50,5 | 5408 |
4x4 | FFr 0440 UNe | 14,4 | 282 | 5x120 | FFr 51200 UNe | 54,5 | 6731 |
4x6 | FFr 0460 UNe | 15,9 | 371 | 5x150 | FFr 51500 UNe | 62,3 | 8427 |
4x10 | FFr 4100 UNe | 18,5 | 566 | 5x185 | FFr 51850 UNe | 67,6 | 10124 |
4x16 | FFr 4160 UNe | 22,8 | 919 | 5x240 | FFr 52400 UNe | 77,2 | 13335 |
3x25+1x16 | FFr 2516 UNe | 25,7 | 1237 | 5x300 | FFr 53000 UNe | 86,6 | 16552 |
3x35+1x16 | FFr 3516 UNe | 27,5 | 1545 | -- | -- | -- | -- |