Control

MX CONPREX ®
Multiconductor - XLPE/PVC - 600 Volt - 90ºC - ICEA S-73-532
Download PDF datasheet

Attributes

  • Flexible Stranded Conductors
  • Sequentially Marked
  • Sunlight resistant
  • Mineral oil resistant

Certifications

Applications

Control, signalling, measuring and protective equipment; electric controls of industrial installations.
Suitable for overhead trays, direct earth burial or duct-buried installations.

features

Temperature rating: 90ºC (operating), 130°C (overload), 250°C (short circuit).
Voltage rating: 600V AC.
Construction requirements: As per ICEA S 73-532.
Nec Code: Compliante with Art. 310 - Art. 501 classified areas Cl1 Div.2 and Cl2 Div.2.
Conductor requirements: As per ASTM B 174.

description

Conductor: Annealed electrolytic copperflexible stranding.
Insulation: XLPE (crosslinked polyethylene).
Identification: According to Method 3 Table E-2; black  and printed in white or yellow.
Sheath: Black PVC; sunlight and mineral-oil resistant.

optionals

Shield: Annealed copper tape helical wrap with 100% coverage and 20% overlap (W).
Armour: Zinc-plated steel wire serve or double zinc-plated steel tape spiral wrap.

installation

Assembly: Minimum bend radius is 7xOD (unarmoured versions) or 12xOD (armoured versions).
Maximum pulling tension: 5daN/sq mm on copper conductors. Wire-armoured cables can withstand 10daN/sq mm on the armour wires.
Assembly temperature: 5ºC or higher.

alternatives

Conductor: Class B semi-rigid stranded cable per ASTM B 8 can be supplied upon request.
Fire requirements: As per ICEA T 30-520 -Fire-retardancy.
Identification: According to Method 3 Table E-1 with other colour bases, Method 1 Table E-1, Method 1 Table E-2.

Tables

General Properties



Gauge AWG Electrical resistance at 90ºC in AC Ohm/km Current-carrying capacity in free air at 40ºC (*)
2x  Ampere 4x  Ampere 7x  Ampere 10x Ampere 19x Ampere 30x Ampere 37x Ampere 48x Ampere
16 17.5 22 17.5 15 11 11 10 9 7.5
14 11.0 32 25.5 22 16 16 14 13 11
12 6.9 36 29 25.5 18 18 16 15 13
10 4.3 50 40 35 25 25 22.5 20 17.5

(*) According to NEC 2008, tables 310.15 and 310.17.

Dimensions & Weight



Conductors x gauge Nª x AWG Standard Shielded
Code Outside diameter mm Weight kg/km Code Under shield diameter mm Outside diameter mm Weight kg/km
2x16 MX 0216 7.8 82 MX 0216 W 11 14.4 280
3x16 MX 0316 8.3 97 MX 0316 W 11 14.4 286
4x16 MX 0416 9 116 MX 0416 W 11 14.4 290
5x16 MX 0516 9.8 140 MX 0516 W 11 14.4 297
7x16 MX 0716 10.6 173 MX 0716 W 11 14.4 309
10x16 MX 1016 14 244 MX 1016 W 12.9 16.3 356
12x16 MX 1216 14.4 278 MX 1216 W 13.4 16.7 393
14x16 MX 1416 15.4 316 MX 1416 W 14.4 17.7 439
16x16 MX 1616 16.2 358 MX 1616 W 15.2 18.5 487
19x16 MX 1916 17 407 MX 1916 W 16 19.4 546
21x16 MX 2116 17.9 447 MX 2116 W 16.8 20.2 589
24x16 MX 2416 19.5 504 MX 2416 W 18.5 22.9 713
27x16 MX 2716 19.9 553 MX 2716 W 18.9 23.3 767
30x16 MX 3016 22 660 MX 3016 W 20.4 24.9 879
32x16 MX 3216 22.8 704 MX 3216 W 21.2 25.7 930
37x16 MX 3716 23.6 787 MX 3716 W 22.1 26.5 1022
48x16 MX 4816 26.5 989 MX 4816 W 25 29.4 1252
2x14 MX 0214 9 113 MX 0214 W 11 14.4 288
3x14 MX 0314 9.6 137 MX 0314 W 11 14.4 298
4x14 MX 0414 10.5 166 MX 0414 W 11 14.4 306
5x14 MX 0514 11.4 201 MX 0514 W 11 14.4 317
7x14 MX 0714 12.4 250 MX 0714 W 11.7 15.1 364
10x14 MX 1014 16.3 347 MX 1014 W 15.3 18.7 481
12x14 MX 1214 16.9 403 MX 1214 W 15.8 19.2 512
14x14 MX 1414 18.1 460 MX 1414 W 17 20.4 603
16x14 MX 1614 19 519 MX 1614 W 18 22.4 723
19x14 MX 1914 20.1 599 MX 1914 W 19 23.4 810
21x14 MX 2114 22.1 703 MX 2114 W 20.6 25 923

W = annealed copper tape helical wrap  

Dimensions & Weight



Conductors x gauge Nª x AWG Standard Shielded
Code Outside diameter mm Weight kg/km Code Under shield diameter mm Outside diameter mm Weight kg/km
27x14 MX 2714 24,6 873 MX 2714 W 23,1 27,6 1124
30x14 MX 3014 25,8 958 MX 3014 W 24,3 28,8 1220
32x14 MX 3214 26,8 1024 MX 3214 W 25,3 29,8 1296
37x14 MX 3714 27,8 1154 MX 3714 W 26,3 30,8 1436
48x14 MX 4814 31,4 1463 MX 4814 W 29,9 34,3 1773
2x12 MX 0212 10 151 MX 0212 W 11 14,4 304
3x12 MX 0312 10,7 187 MX 0312 W 11 14,4 322
4x12 MX 0412 11,7 228 MX 0412 W 11 14,4 337
5x12 MX 0512 12,7 277 MX 0512 W 12,1 15,4 394
7x12 MX 0712 14,7 378 MX 0712 W 13,6 17 497
10x12 MX 1012 18,3 488 MX 1012 W 17,2 20,6 633
12x12 MX 1212 18,9 566 MX 1212 W 17,8 22,2 765
14x12 MX 1412 20,3 651 MX 1412 W 19,2 23,6 863
16x12 MX 1612 22,4 789 MX 1612 W 20,9 25,3 1012
19x12 MX 1912 23,6 908 MX 1912 W 22,0 26,5 1143
21x12 MX 2112 24,7 990 MX 2112 W 23,2 27,7 1242
24x12 MX 2412 27,1 1128 MX 2412 W 25,5 30,0 1396
27x12 MX 2712 27,6 1240 MX 2712 W 26,1 30,6 1521
30x12 MX 3012 29 1365 MX 3012 W 27,5 32,0 1659
32x12 MX 3212 30.2 1463 MX 3212 W 28,6 33,1 1762
37x12 MX 3712 31,3 1655 MX 3712 W 29,8 34,3 1972
48x12 MX 4812 35,4 2107 MX 4812 W 33,9 38,3 2456
2x10 MX 0210 11,3 209 MX 0210 W 11 14,4 330
3x10 MX 0310 12 259 MX 0310 W 11,3 14,7 371
4x10 MX 0410 13,9 342 MX 0410 W 12,9 16,2 456
5x10 MX 0510 15,2 420 MX 0510 W 14,1 17,5 544
7x10 MX 0710 16,5 532 MX 0710 W 15,5 18,9 670
10x10 MX 1010 20,7 695 MX 1010 W 19,7 24,1 916
12x10 MX 1210 22,4 862 MX 1210 W 20,9 25,4 1091
14x10 MX 1410 24 988 MX 1410 W 22,5 27 1233
16x10 MX 1610 25,3 1124 MX 1610 W 23,8 28,3 1381
19x10 MX 1910 26,7 1302 MX 1910 W 25,2 29,6 1567
21x10 MX 2110 28 1425 MX 2110 W 26,5 31 1709
24x10 MX 2410 30,7 1619 MX 2410 W 29,2 33,7 1931
27x10 MX 2710 31,4 1797 MX 2710 W 29,9 34,3 2108
30x10 MX 3010 33 1980 MX 3010 W 31,5 36 2314
32x10 MX 3210 34,3 2116 MX 3210 W 32,8 37,3 2463
37x10 MX 3710 35,7 2415 MX 3710 W 34,2 38,6 2767
48x10 MX 4810 40,4 3082 MX 4810 W 38,9 44,9 3637

W = annealed copper tape helical wrap 

powered by