Control

MA COPERCOM®
Multiconductor - shielded - PVC - Nylon/PVC - 600V - 90ºC
ICEA S-73-532
Download PDF datasheet

Attributes

  • Flexible Stranded Conductors
  • Sequentially Marked
  • Fire-retardant
  • Electromagnetic interference protection
  • Sunlight resistant
  • Mineral oil resistant

Certifications

Applications

Control, signalling, measuring and protective equipment; electric controls of industrial installations.
Suitable for overhead trays, direct earth burial or duct-buried installations.

features

Temperature rating: 90ºC (operating), 160°C (short circuit)
Voltage rating: 600V AC.
Construction: As per ICEA S 73-532.
Fire requirements: As per ICEA T 30-520 -Fire retardancy.
NEC Code:
  Compliant with Art. 310 - Art. 501 classified areas Cl1 Div.2 and Cl2 Div.2.
Conductor requirements: As per ASTM B 174
.

description

Conductor: Annealed electrolytic copperflexible stranding.
Insulation:
PVC/Nylon.
Identification: According to Method 3 Table E-2; black  and printed in white or yellow.
Shield: Aluminium/polyester tape helical wrap with 100% coverage and 25% overlap. Drain wire in contact with the aluminium side of the tape. Drain consists of a 7-wire tinned copper thread.
Sheath: Black PVC; sunlight and mineral-oil resistant.

optionals

Armour: Zinc-plated steel wire serve or double zinc-plated steel tape spiral wrap.

installation

Assembly: Minimum bend radius is 7xOD (unarmoured versions) or 12xOD (armoured versions).
Maximum pulling tension: 5daN/sq mm on copper conductors. Wire-armoured cables can withstand 10daN/sq mm on the armour wires.
Assembly temperature: 5ºC or higher.

alternatives

Conductor: ASTM B 8 compliant class B semi-rigid stranded cable can be supplied upon request.
Identification: According to Method 3 Table E-1 with other colour bases, Method 1 Table E-1, Method 1 Table E-2.

Tables

Dimensions & Weight



Conductors X cross-section N° x AWG Code Outside diameter mm Weight kg/km
2x16 MA 0216 7,4 73
3x16 MA 0316 7,8 92
4x16 MA 0416 8,6 115
5x16 MA 0516 9,3 139
7x16 MA 0716 10 173
10x16 MA 1016 12,3 238
12x16 MA 1216 12,7 274
14x16 MA 1416 14,4 338
16x16 MA 1616 15,1 379
19x16 MA 1916 15,8 432
21x16 MA 2116 16,6 474
24x16 MA 2416 18,1 535
27x16 MA 2716 18,5 590
30x16 MA 3016 19,4 648
32x16 MA 3216 20,1 689
37x16 MA 3716 21,9 829
48x16 MA 4816 24,5 1041
2x14 MA 0214 8,3 96
3x14 MA 0314 8,8 124
4x14 MA 0414 9,6 154
5x14 MA 0514 10,4 188
7x14 MA 0714 11,2 238
10x14 MA 1014 14,6 353
12x14 MA 1214 15,1 408
14x14 MA 1414 16,1 464

Electrical Characteristics



Gauge AWG Electrical resistance at 90ºC in AC Ohm/km Current-carrying capacity in free air at 40ºC (*)
2x  Ampere 4x  Ampere 7x  Ampere 10x Ampere 19x Ampere 30x Ampere 37x Ampere 48x Ampere
16 17.5 22 17.5 15 11 11 10 9 7.5
14 11.0 32 25.5 22 16 16 14 13 11
12 6.9 36 29 25.5 18 18 16 15 13
10 4.3 50 40 35 25 25 22.5 20 17.5

(*) According to NEC 2008, tables 310.15 and 310.17.

Dimensions & Weight



Conductors X cross-section N° x AWG Code Outside diameter mm Weight kg/km
16x14 MA 1614 17 527
19x14 MA 1914 17,8 605
21x14 MA 2114 18,7 663
24x14 MA 2414 20,5 754
27x14 MA 2714 21,9 879
30x14 MA 3014 23 968
32x14 MA 3214 23,8 1028
37x14 MA 3714 24,7 1165
48x14 MA 4814 27,7 1471
2x12 MA 0212 9,1 127
3x12 MA 0312 9,7 170
4x12 MA 0412 10,5 212
5x12 MA 0512 11,4 260
7x12 MA 0712 12,4 338
10x12 MA 1012 16,2 499
12x12 MA 1212 16,7 580
14x12 MA 1412 17,9 667
16x12 MA 1612 18,8 753
19x12 MA 1912 19,8 875
21x12 MA 2112 21,8 1008
24x12 MA 2412 23,8 1144
27x12 MA 2712 24,3 1265
30x12 MA 3012 25,5 1393
32x12 MA 3212 26,5 1488
37x12 MA 3712 27,5 1694
48x12 MA 4812 31 2158
2x10 MA 0210 10,9 185
3x10 MA 0310 11,6 252
4x10 MA 0410 12,7 441
5x10 MA 0510 13,9 549
7x10 MA 0710 15,2 710
10x10 MA 1010 19 1045
12x10 MA 1210 19,6 1197
14x10 MA 1410 21,1 1392
16x10 MA 1610 22,3 1585
19x10 MA 1910 23,6 1837
21x10 MA 2110 24,9 2035
24x10 MA 2410 27,4 2371
27x10 MA 2710 28,1 2604
30x10 MA 3010 29,6 2891
32x10 MA 3210 30,8 3107
37x10 MA 3710 32,1 3518
48x10 MA 4810 36,5 4554
powered by