Industrial Automation
EC ARCOMP ®
Shielded multiconductor - 500V - 80°C - VDE 0812

Attributes
Double Shielding
Sequentially Marked
Fire-retardant
Electromagnetic interference protection
Applications
Suitable for data, and digital and analog signal transmission; equipped with protection against electromagnetic disturbances.
features
Temperature rating: 80°C maximum.
Voltage rating: 500V.
Construction requirements: As per VDE 0812.
Fire requirements: As per IEC 60332-1 and IRAM NM IEC 60332-1.
Conductor requirements: AS per IEC 60228 and IRAM NM 280.
description
Conductor: Annealed tinned electrolytic copper, class 2 stranding.
Insulation: PVC.
Identification:
- 2 conductors: | |||||
- 3 conductors: | |||||
- 4 conductors: | |||||
- 5 conductors: | |||||
- 6 conductors or greater: | White numbered |
Shield: Aluminium-polyester tape helical wrap plus tinned-copper braid with 85% coverage.
Sheath: Grey PVC; flame-retardant.
Stripping: Polyamide ripcord under the sheath.
installation
Assembly: Minimum bend radius is 7xOD (unarmoured versions) and 12xOD (armoured versions).
Maximum pulling tension: 5daN/sq mm on copper conductors.
Assembly temperature: 5ºC or higher.
Tables
Electrical Characteristics
Description | Unit | Characteristics | ||||
---|---|---|---|---|---|---|
Nominal cross-section | sq mm | 0.35 | 0.50 | 0.75 | 1.00 | 1.50 |
Electrical resistance at 20ºC | ohm/km | 59.9 | 40.1 | 24.8 | 18.2 | 12.2 |
Capacitance | pF/m | 97 | 102 | 110 | 117 | 116 |
Dimensions & Weight
Number of conductors | 0.35 sq mm | 0.50 sq mm | 0.75 sq mm | ||||||
---|---|---|---|---|---|---|---|---|---|
Code | Diameter mm | Weight kg/km | Code | Diameter mm | Weight kg/km | Code | Diameter mm | Weight kg/km | |
2 | EC 0203 | 5.1 | 36 | EC 0205 | 5.6 | 44 | EC 0207 | 6.2 | 55 |
3 | EC 0303 | 5.3 | 42 | EC 0305 | 5.9 | 53 | EC 0307 | 6.5 | 67 |
4 | EC 0403 | 5.7 | 50 | EC 0405 | 6.3 | 63 | EC 0407 | 7.0 | 80 |
5 | EC 0503 | 6.3 | 61 | EC 0505 | 7.0 | 76 | EC 0507 | 7.8 | 98 |
7 | EC 0703 | 6.8 | 74 | EC 0705 | 7.7 | 97 | EC 0707 | 8.5 | 125 |
12 | EC 1203 | 8.8 | 119 | EC 1205 | 9.9 | 152 | EC 1207 | 10.7 | 192 |
19 | EC 1903 | 10.1 | 164 | EC 1905 | 11.3 | 212 | EC 1907 | 12.8 | 292 |
24 | EC 2403 | 11.5 | 200 | EC 2405 | 13.4 | 280 | EC 2407 | 14.9 | 367 |
Dimensions & Weight
Number of conductors |
1.00 sq mm | 1.50 sq mm | ||||
---|---|---|---|---|---|---|
Code | Diameter mm | Weight kg/km | Code | Diameter mm | Weight kg/km | |
2 | EC 0210 | 6.6 | 63 | EC 0215 | 7.8 | 88 |
3 | EC 0310 | 6.9 | 78 | EC 0315 | 8.2 | 110 |
4 | EC 0410 | 7.6 | 98 | EC 0415 | 8.8 | 134 |
5 | EC 0510 | 8.2 | 115 | EC 0515 | 9.6 | 159 |
7 | EC 0710 | 9.1 | 149 | EC 0715 | 10.6 | 208 |
12 | EC 1210 | 11.7 | 237 | EC 1215 | 14.0 | 349 |
19 | EC 1910 | 13.7 | 354 | EC 1915 | 16.6 | 518 |
24 | EC 2410 | 16.1 | 451 | EC 2415 | 19.3 | 661 |