Electronic Instrumentation
AN MILIAR ® single
Pair, triad and quad - 600V - 90°C - TC - UL 1277

Attributes
Sequentially Marked
International Market
Fire-retardant
Hydrocarbon-resistant
Sunlight resistant
Certifications
Applications
Electronic instrumentation, analog and digital signal circuits (4-20mA).
Intrinsically safe circuits.
Gas and/or fluid leak detection systems.
Pressure, temperature and volume measuring and monitoring equipment.
Alarm signal monitoring.
features
Temperature rating: 90ºC maximum.
Voltage rating: 600V.
Construction requirements: As per UL 1277.
Fire requirements: As per UL 1685.
Conductor requirements: As per ASTM B8, class B.
NEC Code: Compliant with Art. 340 TC, Art. 501 classified locations Class 1 Div.2 and Class 2 Div.2.
Hydrocarbon requirements: As per NFC 32-200 and ASTM D 1239.
description
Conductor: Annealed electrolytic copper, 7-wire stranding, class B.
Insulation: PVC/Nylon. (THHN)
Identification:
Standard | Intrinsically Safe | |||||||
- Pair: | ||||||||
- Triad: | ||||||||
- Quad: |
Lay length: 50 mm (20 twists/m).
Unshielded pair: Polyester tape wrap.
Shield: Aluminium-polyester tape helical wrap plus tinned-copper drain-wire conductor, 7-wire stranding, class B.
Sheath: Black PVC (blue for intrinsically safe systems); fire-retardant; sunlight and hydrocarbon-resistant.
Stripping: Polyamide ripcord under the sheath.
optionals
Sheath: Fire-retardant and mineral-oil-resistant.
installation
Assembly: Minimum bend radius is 7xOD (unarmoured versions).
Maximum pulling tension: 5daN/sq mm on copper conductors.
Assembly temperature: 5ºC or higher.
alternatives
Construction requirements: As per ICEA S-82-552 and ICEA S-73-532
Materials: These data are relevant to the standard version of this cable. Other solutions can be made to order based on the materials and construction alternatives described in the technical information appendix.
Tables
Electrical Characteristics
Description | Unit | 20 AWG /0.52 sq mm | 18 AWG /0.82 sq mm | 16 AWG /1.31 sq mm | 14 AWG /2.08 sq mm | 12 AWG /3.31 sq mm | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | ||
Electrical resistance at 20ºC in DC | Ohm/km | 35.78 | 35.78 | 22.78 | 22.78 | 14.25 | 14.25 | 8.94 | 8.94 | 5.63 | 5.63 |
Mutual capacitance between conductors | pF/m | 86 | 160 | 80 | 136 | 101 | 186 | 112 | 210 | 125 | 235 |
Characteristic impedance | Ohm | 87 | 50 | 100 | 55 | 75 | 40 | 67 | 36 | 60 | 32 |
Mutual inductance between conductors | uH/km | 636 | 636 | 689 | 689 | 578 | 578 | 544 | 544 | 515 | 515 |
pF/m = Mutual capacitance between conductors expressed in picoFarad/ per metre.uH/km = Mutual inductance between conductors expressed in microHenry per kilometre.
Dimensions & Weight
Type | Gauge AWG | Standard | |||
---|---|---|---|---|---|
Conductor | Drain wire | Code | Outside diameter mm | Weight kg/km | |
Unshielded pair | 20 | -- | AN 0500 | 5.8 | 40 |
Unshielded pair | 18 | -- | AN 0510 | 6.5 | 52 |
Unshielded pair | 16 | -- | AN 0520 | 7.2 | 67 |
Unshielded pair | 14 | -- | AN 0530 | 7.9 | 86 |
Unshielded pair | 12 | -- | AN 0580 | 8.9 | 117 |
Shielded pair | 20 | 22 | AN 5000 | 5.9 | 45 |
Shielded pair | 18 | 20 | AN 5100 | 6.6 | 58 |
Shielded pair | 16 | 18 | AN 5200 | 7.3 | 76 |
Shielded pair | 14 | 18 | AN 5300 | 8.0 | 96 |
Shielded pair | 12 | 18 | AN 5800 | 9.0 | 126 |
Shielded triad | 20 | 22 | AN 6000 | 6.2 | 54 |
Shielded triad | 18 | 20 | AN 6100 | 7.0 | 72 |
Shielded triad | 16 | 18 | AN 6200 | 7.6 | 94 |
Shielded triad | 14 | 18 | AN 6300 | 8.5 | 124 |
Shielded triad | 12 | 18 | AN 6800 | 9.5 | 167 |
Shielded quad | 20 | 22 | AN 9000 | 6.7 | 65 |
Shielded quad | 18 | 20 | AN 9100 | 7.5 | 87 |
Shielded quad | 16 | 18 | AN 9200 | 8.3 | 115 |
Shielded quad | 14 | 18 | AN 9300 | 9.2 | 153 |
Shielded quad | 12 | 18 | AN 9800 | 10.4 | 210 |