Control

CY COPERCOM ®
Multiconductor - PVC-Nylon/PVC - 600 Volt - 90ºC - UL 1277
Download PDF datasheet

Attributes

  • NEC Code
  • Wet Locations
  • Fire-retardant
  • Hydrocarbon-resistant
  • Sunlight resistant
  • Mineral oil resistant

Certifications

Applications

Control, signalling, measuring and protection equipment and electrical commands for industrial installations. Suitable for aerial tray installation, duct buried or directly buried. Manufactured in compliance with the National Electrical Code ANSI/NFPA 70 of the US and the National Electrical Code NOM-001, SEDE Mexico.

features

Temperature rating: 90ºC (service), 160ºC (short circuit)
Voltage rating: 600 Volt AC.
Construction requirements: As per UL 1277
Fire requirements: As per UL 1685 - Fire retardancy.
NEC code: Art 336  - Art 501 classified areas Cl 1 Div 2 and Cl 2 Div 2
Conductor requiremetns: As per ASTM B 8

description

Conductor: Annealed electrolytic copper, 7-wire stranding, class B.
Insulation: PVC/Nylon (THWN-2)
Indentification: Black with white alphanumeric printing.
Sheath: Black PVC, sunlight and hydrocarbon-resistant,

 

optionals

Shielding: If necessary, these cables can be provided with any of the following electromagnetic shields

  • Helically applied Aluminium – Polyester tape plus tinned copper drain wire (A)
  • Annealed copper tape helical wrap with 100% coverage and 20% overlap (W)
  • Annealed Electrolytic Copper wires braid with 80% overlap (M)
  • Annealed Tinned Electrolytic Copper wires braid with 80% overlap (Ñ)
  • Helically applied annealed electrolytic copper wires (B)

installation

Assembly: Minimun bend radius is 7xOD.
Maximun pulling tension: 5daN/sq mm on copper conductors.
Assembly temperature: 5ºC or higher.

Tables

Electrical Characteristics



Gauge AWG Electrical resistance at 90ºC in AC. Ohm/km Current-carrying capacity in free air at 40ºC (*)
2x Amper 4x Amper 7x Amper 10x Amper 19x Amper 30x Amper 37x Amper 48x Amper
14 11,0 32 25,5 22 16 16 14 13 11
12 6,9 36 29 25,5 18 18 16 15 13
10 4,3 50 40 35 25 25 22,5 20 17,5

(*) Acording to NFPA70, table 310.15 and 310.17

Dimension Characteristics



-

Conductors x sections Nª x AWG Code Outside diameter mm Weight Kg/km
2x14 CY 0214 7,9 100
3x14 CY 0314 8,4 124
4x14 CY 0414 9,1 150
5x14 CY 0514 9,9 183
7x14 CY 0714 10,8 235
10x14 CY 1014 14,5 333
12x14 CY 1214 14,9 384
14x14 CY 1414 15,6 437
16x14 CY 1614 16,5 498
19x14 CY 1914 17,3 574
21x14 CY 2114 18,2 631
24x14 CY 2414 20,1 715
27x14 CY 2714 20,6 794
30x14 CY 3014 22,3 920
32x14 CY 3214 23,1 979
37x14 CY 3714 24 1112
48x14 CY 4814 27,2 1411
2x12 CY 0212 8,9 137
3x12 CY 0312 9,4 171
4x12 CY 0412 10,3 212
5x12 CY 0512 11,2 258
7x12 CY 0712 12,2 334

Dimension Characteristics



-

Conductors x sections Nª x AWG Code Outside diameter mm Weight Kg/km
10x12 CY 1012 16,1 470
12x12 CY 1212 16,6 547
14x12 CY 1412 17,8 629
16x12 CY 1612 18,7 713
19x12 CY 1912 19,7 828
21x12 CY 2112 20,7 910
24x12 CY 2412 23,7 1087
27x12 CY 2712 24,2 1203
30x12 CY 3012 25,4 1325
32x12 CY 3212 26,3 1410
37x12 CY 3712 27,3 1606
48x12 CY 4812 30,8 2048
2x10 CY 0210 10,6 203
3x10 CY 0310 11,3 258
4x10 CY 0410 12,4 321
5x10 CY 0510 14,3 418
7x10 CY 0710 15,6 540
10x10 CY 1010 19,5 713
12x10 CY 1210 20,1 834
14x10 CY 1410 22,6 1011
16x10 CY 1610 23,8 1147
19x10 CY 1910 25,1 1335
21x10 CY 2110 26,3 1461
24x10 CY 2410 28,8 1661
27x10 CY 2710 29,5 1849
30x10 CY 3010 31 2039
32x10 CY 3210 32,2 2176
37x10 CY 3710 33,4 2481
48x10 CY 4810 37,8 3175