Marlew

Clad series UM A-H

300 Volt
Cu 20 up to 14 AWG
PVC 105°C / PVC
UL 13 PLTC

Electronic instrumentation circuits. Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and monitoring equipment. Alarm signal monitoring. Installed in trays, cable ladders, in direct open air or indoors, directly buried or buried in a trench or in ducts.

Features

  • Temperature rating: 105°C

  • Voltage rating: 300 Volt

  • Construction requirements: UL 13 PLTC type - UL 2250 ITC type

  • Conductor requirements: ASTM B8 Class B

  • Conductor: Annealed electrolytic copper, 7-wire stranding

  • Insulation: PVC

  • Assembly: Conductors gathered in a crown + polyester tape

  • Shield: Aluminum-polyester tape with tinned copper drain wire

  • Inner sheath: PVC

  • Armour: Galvanized steel wire armour

  • Sheath: Flame retardant PVC, sunlight, and hydrocarbons resistant

  • Fire requirements: As per UL 1685

  • Hydrocarbons requirements: NFC 32-200 – ASTM D

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • NEC Code (NFPA 70): Art. 725 PLTC – Art. 727 ITC– Art. 501 classified areas CL1 Div.2 y Cl2 Div.2

Fire-retardant

Fire-retardant

Hydrocarbon resistant

Hydrocarbon resistant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Refinery use

Refinery use

Tray cable

Tray cable

Identification

Standard
Conductors
Multiconductors numbered conductors

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering can be used upon request. Instrumentation cables can be manufactured under a different standard, such as ICEA S 73-532, complying with other electrical and dimensional parameters.

ELECTRICAL CHARACTERISTICS

Description Unit 20AWG 18AWG 16AWG 14AWG
Electrical resistance in D.C. at 20°COhm/km34.9922.313.978.76
Mutual Capacitance between conductorspF/m120110130140
Mutual inductance between conductorsuH/Km588641544553

pF/m = Mutual Capacitance between conductors, expressed in picofarad per meter / uH/km = Mutual inductance between conductors, expressed in microhenry per kilometer.

DIMENSIONS & WEIGHT

N° Conductors AWG Diameter under armour mm External diameter mm Weight kg/km Code
2205.18.8163UM-A-H 2x20
35.49.0176UM-A-H 3X20
45.89.4190UM-A-H 4X20
56.210.4220UM-A-H 5x20
66.710.8239UM-A-H 6X20
76.710.8246UM-A-H 7X20
98.012.2296UM-A-H 9X20
128.812.9336UM-A-H 12X20
159.613.8377UM-A-H 15X20
1810.614.7432UM-A-H 18X20
2111.115.2466UM-A-H 21X20
2412.216.8534UM-A-H 24X20
2712.417.0561UM-A-H 27X20
3012.817.4594UM-A-H 30X20
3213.217.9621UM-A-H 32X20
3613.718.4658UM-A-H 36X20
2185.99.5191UM-A-H 2x18
36.210.3220UM-A-H 3X18
46.710.8243UM-A-H 4X18
57.511.6276UM-A-H 5x18
68.112.2301UM-A-H 6X18
78.112.2311UM-A-H 7X18
99.313.5366UM-A-H 9X18
1210.814.9445UM-A-H 12X18
1511.816.4522UM-A-H 15X18
1812.417.0569UM-A-H 18X18
2112.917.6616UM-A-H 21X18
2414.318.9688UM-A-H 24X18
2714.619.2727UM-A-H 27X18
3015.119.7773UM-A-H 30X18
3216.120.8838UM-A-H 32X18
3616.721.4895UM-A-H 36X18
2166.510.6227UM-A-H 2x16
36.811.0250UM-A-H 3X16
47.711.8293UM-A-H 4X16
58.312.4323UM-A-H 5x16
69.013.1357UM-A-H 6X16
79.013.1373UM-A-H 7X16
910.916.3521UM-A-H 9X16
1212.016.7560UM-A-H 12X16
1513.217.9642UM-A-H 15X16
1813.918.5705UM-A-H 18X16
2114.619.2773UM-A-H 21X16
2416.621.3893UM-A-H 24X16
2717.021.6949UM-A-H 27X16
3017.622.71042UM-A-H 30X16
3218.223.31090UM-A-H 32X16
3618.924.01174UM-A-H 36X16
2148.012.2288UM-A-H 2x14
38.512.6326UM-A-H 3X14
49.213.4371UM-A-H 4X14
510.514.7438UM-A-H 5x14
611.416.0503UM-A-H 6X14
711.416.0529UM-A-H 7X14
913.317.9635UM-A-H 9X14
1214.719.3748UM-A-H 12X14
1516.721.4896UM-A-H 15X14
1817.622.81026UM-A-H 18X14
2118.523.61128UM-A-H 21X14
2420.525.81309UM-A-H 24X14
2720.926.31401UM-A-H 27X14
3021.727.01497UM-A-H 30X14
3223.028.61664UM-A-H 32X14
3623.929.41797UM-A-H 36X14