Clad series UM A-H

Steel wire armour

300 Volt
Cu 20 up to 14 AWG
PVC 105°C / PVC
UL 13 PLTC

Electronic instrumentation circuits. Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and monitoring equipment. Alarm signal monitoring. Installed in trays, cable ladders, in direct open air or indoors, directly buried or buried in a trench or in ducts.

Features

  • Temperature rating: 105°C

  • Voltage rating: 300 Volt

  • Construction requirements: UL 13 PLTC type - UL 2250 ITC type

  • Conductor requirements: ASTM B8 Class B

  • Conductor: Annealed electrolytic copper, 7-wire stranding

  • Insulation: PVC

  • Assembly: Conductors gathered in a crown + polyester tape

  • Shield: Aluminum-polyester tape with tinned copper drain wire

  • Inner sheath: PVC

  • Armour: Galvanized steel wire armour

  • Sheath: Flame retardant PVC, sunlight, and hydrocarbons resistant

  • Fire requirements: As per UL 1685

  • Hydrocarbons requirements: NFC 32-200 – ASTM D

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • NEC Code (NFPA 70): Art. 725 PLTC – Art. 727 ITC– Art. 501 classified areas CL1 Div.2 y Cl2 Div.2

Fire-retardant

Fire-retardant

Hydrocarbon resistant

Hydrocarbon resistant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Refinery use

Refinery use

Tray cable

Tray cable

Direct burial

Direct burial

Identification

Standard
Conductors
Multiconductors numbered conductors

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering can be used upon request. Instrumentation cables can be manufactured under a different standard, such as ICEA S 73-532, complying with other electrical and dimensional parameters.

ELECTRICAL CHARACTERISTICS

Description Unit 20AWG 18AWG 16AWG 14AWG
Electrical resistance in D.C. at 20°COhm/km34.9922.313.978.76
Mutual Capacitance between conductorspF/m120110130140
Mutual inductance between conductorsuH/Km588641544553

pF/m = Mutual Capacitance between conductors, expressed in picofarad per meter / uH/km = Mutual inductance between conductors, expressed in microhenry per kilometer.

DIMENSIONS & WEIGHT

N° Conductors AWG Diameter under armour mm External diameter mm Weight kg/km Code
2205.18.8163UM 0220 AH
35.49.0176UM 0320 AH
45.89.4190UM 0420 AH
56.210.4220UM 0520 AH
66.710.8239UM 0620 AH
76.710.8246UM 0720 AH
98.012.2296UM 0920 AH
128.812.9336UM 1220 AH
159.613.8377UM 1520 AH
1810.614.7432UM 1820 AH
2111.115.2466UM 2120 AH
2412.216.8534UM 2420 AH
2712.417.0561UM 2720 AH
3012.817.4594UM 3020 AH
3213.217.9621UM 3220 AH
3613.718.4658UM 3620 AH
2185.99.5191UM 0218 AH
36.210.3220UM 0318 AH
46.710.8243UM 0418 AH
57.511.6276UM 0518 AH
68.112.2301UM 0618 AH
78.112.2311UM 0718 AH
99.313.5366UM 0918 AH
1210.814.9445UM 1218 AH
1511.816.4522UM 1518 AH
1812.417.0569UM 1818 AH
2112.917.6616UM 2118 AH
2414.318.9688UM 2418 AH
2714.619.2727UM 2718 AH
3015.119.7773UM 3018 AH
3216.120.8838UM 3218 AH
3616.721.4895UM 3618 AH
2166.510.6227UM 0216 AH
36.811.0250UM 0316 AH
47.711.8293UM 0416 AH
58.312.4323UM 0516 AH
69.013.1357UM 0616 AH
79.013.1373UM 0716 AH
910.916.3521UM 0916 AH
1212.016.7560UM 1216 AH
1513.217.9642UM 1516 AH
1813.918.5705UM 1816 AH
2114.619.2773UM 2116 AH
2416.621.3893UM 2416 AH
2717.021.6949UM 2716 AH
3017.622.71042UM 3016 AH
3218.223.31090UM 3216 AH
3618.924.01174UM 3616 AH
2148.012.2288UM 0214 AH
38.512.6326UM 0314 AH
49.213.4371UM 0414 AH
510.514.7438UM 0514 AH
611.416.0503UM 0614 AH
711.416.0529UM 0714 AH
913.317.9635UM 0914 AH
1214.719.3748UM 1214 AH
1516.721.4896UM 1514 AH
1817.622.81026UM 1814 AH
2118.523.61128UM 2114 AH
2420.525.81309UM 2414 AH
2720.926.31401UM 2714 AH
3021.727.01497UM 3014 AH
3223.028.61664UM 3214 AH
3623.929.41797UM 3614 AH