series UM A

300 Volt
Cu 20 up to 14 AWG
PVC 105°C / PVC
UL 13 PLTC

Electronic instrumentation circuits. Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and monitoring equipment. Alarm signal monitoring. Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts.

Features

  • Temperature rating: 105°C

  • Voltage rating: 300 Volt

  • Construction requirements: UL 13 PLTC type - UL 2250 ITC type

  • Conductor requirements: ASTM B8 Class B

  • Conductor: Annealed electrolytic copper, 7-wire stranding

  • Insulation: PVC

  • Assembly: Conductors gathered in a crown + polyester tape

  • Shield: Aluminum-polyester tape with tinned copper drain wire

  • Sheath: Flame retardant PVC, sunlight, and hydrocarbons resistant

  • Fire requirements: As per UL 1685

  • Hydrocarbons requirements: NFC 32-200 – ASTM D

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • NEC Code (NFPA 70): Art. 725 PLTC – Art. 727 ITC– Art. 501 classified areas CL1 Div.2 y Cl2 Div.2

Fire-retardant

Fire-retardant

Hydrocarbon resistant

Hydrocarbon resistant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Refinery use

Refinery use

Tray cable

Tray cable

Identification

Standard
Conductors
Multiconductors numbered conductors

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering can be used upon request. Instrumentation cables can be manufactured under a different standard, such as ICEA S 73-532, complying with other electrical and dimensional parameters.

ELECTRICAL CHARACTERISTICS

Description Unit 20AWG 18AWG 16AWG 14AWG
Electrical resistance in D.C. at 20°COhm/km34.9922.313.978.76
Mutual Capacitance between conductorspF/m120110130140
Mutual inductance between conductorsuH/Km588641544553

pF/m = Mutual Capacitance between conductors, expressed in picofarad per meter / uH/km = Mutual inductance between conductors, expressed in microhenry per kilometer.

DIMENSIONS & WEIGHT

N° Conductors AWG External diameter mm Weight kg/km Code
2205.137UM 0220 A
35.445UM 0320 A
45.853UM 0420 A
56.262UM 0520 A
66.771UM 0620 A
76.777UM 0720 A
98.0100UM 0920 A
128.8124UM 1220 A
159.6148UM 1520 A
1810.6182UM 1820 A
2111.1206UM 2120 A
2412.2233UM 2420 A
2712.4254UM 2720 A
3012.8277UM 3020 A
3213.2293UM 3220 A
3613.7322UM 3620 A
2185.950UM 0218 A
36.262UM 0318 A
46.774UM 0418 A
57.591UM 0518 A
68.1105UM 0618 A
78.1115UM 0718 A
99.3143UM 0918 A
1210.8190UM 1218 A
1511.8228UM 1518 A
1812.4262UM 1818 A
2112.9298UM 2118 A
2414.3337UM 2418 A
2714.6370UM 2718 A
3015.1404UM 3018 A
3216.1446UM 3218 A
3616.7492UM 3618 A
2166.563UM 0216 A
36.880UM 0316 A
47.7103UM 0416 A
58.3121UM 0516 A
69.0140UM 0616 A
79.0156UM 0716 A
910.9207UM 0916 A
1212.0260UM 1216 A
1513.2314UM 1516 A
1813.9364UM 1816 A
2114.6416UM 2116 A
2416.6491UM 2416 A
2717.0540UM 2716 A
3017.6591UM 3016 A
3218.2626UM 3216 A
3618.9693UM 3616 A
2148.093UM 0214 A
38.5120UM 0314 A
49.2148UM 0414 A
510.5189UM 0514 A
611.4219UM 0614 A
711.4245UM 0714 A
913.3307UM 0914 A
1214.7390UM 1214 A
1516.7493UM 1514 A
1817.6574UM 1814 A
2118.5658UM 2114 A
2420.5748UM 2414 A
2720.9826UM 2714 A
3021.7907UM 3014 A
3223.0989UM 3214 A
3623.91096UM 3614 A