Clad series MX-F

Steel tape armour

600 Volt
Cu 16 up to 10 AWG
XLPE 90°C
ICEA S 73-532

Control, signalling, measuring and protective equipment; electric controls of industrial installations. Installed in aerial trays, gutters or conduits, under roof or ladder under roof, buried in ducts or directly buried. It has additional mechanical protection.

Features

  • Temperature ratings: 90°C (Operating) – 130°C (Overload) – 250°C (Short Circuit)

  • Voltage rating: 600 Volt A.C.

  • Construction requirements: As per ICEA S 73-532

  • Conductor requirements: ASTM B174

  • Conductor: Annealed electrolytic copper - Flexible stranding

  • Insulation: XLPE (Cross-Linked Polyethylene)

  • Bedding: PVC

  • Armour: Double galvanized steel helical tape

  • Sheath: Flame retardant PVC, sunlight, and mineral oil resistant

  • Fire requirements: As per ICEA T 30-520

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

Fire-retardant

Fire-retardant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Industrial applications

Industrial applications

Tray cable

Tray cable

Direct burial

Direct burial

Identification

Standard
Sheath Conductors
MulticonductorMethod 3 Table E-2

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Gauge AWG Electrical resistance at 20°C in C.C. (Ohm/km) Electrical resistance at 90°C in C.A. at 60Hz (Ohm/km) Current-carrying capacity (1)
2x 4x 7x 10x 19x 30x
1613.9917.841814.412.6998.1
148.7711.18252017.512.512.511.3
125.527.04302421151513.5
103.484.44403228202018

(1) Current-carrying capacity of cables with up to three conductors, installed in ducts or directly buried, up to an ambient temperature of 30ºC, according to chart 310.15 (B)(16) of the NFPA 70. As from four-conductors, we’ve additionally applied the correction factor for more than three conductors from the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable Formation N° Cond. x gauge AWG Diameter under armour mm External diameter mm Weight kg/km Code
7x1610.414.5336MX 0716 F
10x1612.216.3406MX 1016 F
12x1613.918.0488MX 1216 F
14x1614.818.9537MX 1416 F
19x1616.720.8654MX 1916 F
24x1618.422.5766MX 2416 F
30x1620.224.3907MX 3016 F
4x1410.414.5332MX 0414 F
5x1411.315.4379MX 0514 F
7x1412.316.4444MX 0714 F
10x1415.419.5578MX 1014 F
12x1416.520.6651MX 1214 F
14x1417.621.7722MX 1414 F
19x1420.024.1894MX 1914 F
24x1423.127.21125MX 2414 F
30x1425.429.51335MX 3014 F
3x1210.514.6352MX 0312 F
4x1211.515.6406MX 0412 F
5x1212.616.7469MX 0512 F
7x1214.518.6593MX 0712 F
10x1217.121.2731MX 1012 F
12x1218.422.5831MX 1212 F
14x1219.623.7929MX 1412 F
19x1223.327.41232MX 1912 F
24x1225.729.81468MX 2412 F
30x1228.332.41755MX 3012 F
2x1011.215.3383MX 0210 F
3x1011.916.0442MX 0310 F
4x1013.017.1518MX 0410 F
5x1015.019.1640MX 0510 F
7x1016.420.5772MX 0710 F
10x1019.323.4965MX 1010 F
12x1021.825.91169MX 1210 F
14x1023.327.41312MX 1410 F
19x1026.430.51660MX 1910 F
24x1029.233.31997MX 2410 F
30x1032.237.52770MX 3010 F