Marlew

Clad series MM-F

600 Volt
Cu 16 up to 10 AWG
PVC 75°C
ICEA S 73-532

Control, signalling, measuring and protective equipment; electric controls of industrial installations. Installed in aerial trays, gutters or conduits, under roof or ladder under roof, buried in ducts or directly buried. It has additional mechanical protection.

Features

  • Temperature rating: 75ºC (operating), 160°C (short circuit)

  • Voltage rating: 600V AC

  • Construction requirements: As per ICEA S 73-532

  • Conductor requirements: As per ASTM B174

  • Conductor: Annealed electrolytic copper; flexible

  • Insulation: PVC

  • Bedding: PVC

  • Armour: Double galvanized steel helical tape

  • Sheath: PVC fire-retardant; sunlight and mineral-oil resistant

  • Fire requirements: As per ICEA T 30-520

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

Fire-retardant

Fire-retardant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Industrial applications

Industrial applications

Tray cable

Tray cable

Direct burial

Direct burial

Identification

Standard
Sheath Conductors
MulticonductorMethod 3 Table E-2

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Gauge AWG Electrical resistance at 20°C in C.C. (Ohm/km) Electrical resistance at 75°C in AC. a 60Hz (Ohm/km) Current-carrying capacity (1)
2x 4x 7x 10x 19x 30x
1613.9917.0114.411.5107.27.26.5
148.7710.6620161410109
125.526.72252017.512.512.511.3
103.484.23352824.517.517.515.8

(1) Current-carrying capacity of cables with up to three conductors, installed in ducts or directly buried, up to an ambient temperature of 30ºC, according to chart 310.15 (B)(16) of the NFPA 70. As from four-conductors, we’ve additionally applied the correction factor for more than three conductors from the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable Formation N° Cond. x gauge AWG Diameter under armour mm External diameter mm Weight kg/km Code Mat Number Previous Code
10x1812,216,3394MM-F 10x18820039010MM 1018 F
12x1813,918,0473MM-F 12x18820039020MM 1218 F
14x1814,818,9520MM-F 14x18820039030MM 1418 F
19x1816,720,8631MM-F 19x18820039040MM 1918 F
24x1818,422,5737MM 2418 FMM-F 24x18820039050
30x1820,224,3871MM-F 30x18820039060MM 3018 F
7x1611.215.3377MM-F 7x16820039070MM 0716 F
10x1613.918.0492MM-F 10x16820039080MM 1016 F
12x1614.919.0551MM-F 12x16820039090MM 1216 F
14x1615.920.0608MM-F 14x16820039100MM 1416 F
19x1618.022.1746MM-F 19x16820039110MM 1916 F
24x1619.823.9878MM-F 24x16820039120MM 2416 F
30x1622.927.01109MM-F 30x16820039130MM 3016 F
4x1412.216.3413MM-F 4x14820039140MM 0414 F
5x1414.218.3509MM-F 5x14820039150MM 0514 F
7x1415.419.5597MM-F 7x14820039160MM 0714 F
10x1418.122.2726MM-F 10x14820039170MM 1014 F
12x1419.623.7822MM-F 12x14820039180MM 1214 F
14x1421.926.0979MM-F 14x14820039190MM 1414 F
19x1424.828.91213MM-F 19x14820039200MM 1914 F
24x1427.431.51439MM-F 24x14820039210MM 2414 F
30x1430.234.31713MM-F 30x14820039220MM 3014 F
3x1212.216.3425MM-F 3x12820039230MM 0312 F
4x1214.118.2527MM-F 4x12820039240MM 0412 F
5x1215.419.5609MM-F 5x12820039250MM 0512 F
7x1216.820.9723MM-F 7x12820039260MM 0712 F
10x1219.823.9890MM-F 10x12820039270MM 1012 F
12x1222.426.51080MM-F 12x12820039280MM 1212 F
14x1223.928.01205MM-F 14x12820039290MM 1412 F
19x1227.231.31512MM-F 19x12820039300MM 1912 F
24x1230.034.11808MM-F 24x12820039310MM 2412 F
30x1233.138.42541MM-F 30x12820039320MM 3012 F
2x1012.716.8452MM-F 2x10820039330MM 0210 F
3x1014.318.4557MM-F 3x10820039340MM 0310 F
4x1015.619.7650MM-F 4x10820039350MM 0410 F
5x1017.121.2759MM-F 5x10820039360MM 0510 F
7x1018.622.7916MM-F 7x10820039370MM 0710 F
10x1023.127.21208MM-F 10x10820039380MM 1010 F
12x1024.929.01383MM-F 12x10820039390MM 1210 F
14x1026.530.61554MM-F 14x10820039400MM 1410 F
19x1030.235.52316MM-F 19x10820039410MM 1910 F
24x1033.538.82761MM-F 24x10820039420MM 2410 F
30x1037.043.03363MM-F 30x10820039430MM 3010 F