Clad series ME-H

Steel wire armour

600 Volt
Cu 16 up to 10 AWG
XLPE 90°C / LSZH
ICEA S 73-532

Control, signalling, measuring and protective equipment, electric controls of home installations. Use in closed environments with a high concentration of people (airports, hospitals, trains, cinemas, shopping centers, tunnels) and in control rooms with electronic equipment sensitive to the exposure of corrosive gases. Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts. It has additional mechanical protection.

Features

  • Temperature rating: 90ºC (operating),130ºC (overload) and 250ºC (short circuit)

  • Voltage rating: 600 AC

  • Construction requirements: As per ICEA S 73-532

  • Conductor requirements: As per ASTM B174

  • Conductor: Annealed electrolytic copper; flexible

  • Insulation: XLPE (Cross-linked polyethylene)

  • Bedding: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant)

  • Armour: Galvanized steel wire armour

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant), fire-retardant sunlight and oils resistant

  • Fire requirements: As per ICEA T 30-520

  • Standard for halogen absence and corrosive gases: As per IEC 60754-1/2

  • Smoke transparency requirements: As per IEC 61034-1/2

  • Toxicity standard: As per NES 713 – CEI 20.37

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • Water behaviour requirements: Suitable AD7 (Occasional water submersion)

Fire-retardant

Fire-retardant

Halogen free

Halogen free

Low smoke

Low smoke

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Water immersion

Water immersion

Identification

Standard
Sheath Conductors
MulticonductorMethod 3 Table E-2

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Gauge AWG Electrical resistance at 20°C in C.C. (Ohm/km) Electrical resistance at 75°C in AC. a 60Hz (Ohm/km) Current-carrying capacity (1)
2x 4x 7x 10x 19x 30x
1613.9917.841814.412.6998.1
148.7711.18252017.512.512.511.3
125.527.04302421151513.5
103.484.44403228202018

(1) Current-carrying capacity of cables with up to three conductors, installed in ducts or directly buried, up to an ambient temperature of 30ºC, according to chart 310.15 (B)(16) of the NFPA 70. As from four-conductors, we’ve additionally applied the correction factor for more than three conductors from the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable formation N° Cond. x gauge AWG Diameter under armour mm External diameter mm Weight kg/km Code
2x187.211.3243ME 0218 H
3x187.611.7260ME 0318 H
4x188.212.3286ME 0418 H
5x188.913.0320ME 0518 H
7x189.614.5382ME 0718 H
10x1811.317.1568ME 1018 H
12x1812.117.9622ME 1218 H
14x1812.918.7664ME 1418 H
19x1815.421.9947ME 1918 H
24x1816.923.41074ME 2418 H
30x1818.625.11227ME 3018 H
2x167.711.8265ME 0216 H
3x168.112.3289ME 0316 H
4x168.813.0320ME 0416 H
5x169.614.5384ME 0516 H
7x1610.416.2544ME 0716 H
10x1612.218.0641ME 1016 H
12x1613.919.7754ME 1216 H
14x1614.820.6818ME 1416 H
19x1616.723.21093ME 1916 H
24x1618.424.91244ME 2416 H
30x1620.226.71423ME 3016 H
2x149.013.1327ME 0214 H
3x149.514.4385ME 0314 H
4x1410.416.2540ME 0414 H
5x1411.317.1601ME 0514 H
7x1412.318.1680ME 0714 H
10x1415.421.9977ME 1014 H
12x1416.523.01075ME 1214 H
14x1417.624.11172ME 1414 H
19x1420.026.51395ME 1914 H
24x1423.129.61708ME 2414 H
30x1425.433.02227ME 3014 H
2x129.914.8407ME 0212 H
3x1210.516.3560ME 0312 H
4x1211.517.3628ME 0412 H
5x1212.618.4714ME 0512 H
7x1214.520.3867ME 0712 H
10x1217.123.61168ME 1012 H
12x1218.424.91309ME 1212 H
19x1223.329.81813ME 1912 H
24x1225.733.32384ME 2412 H
30x1228.335.92732ME 3012 H
2x1011.217.0598ME 0210 H
3x1011.917.7672ME 0310 H
4x1013.018.8771ME 0410 H
5x1015.021.51043ME 0510 H
7x1016.422.91199ME 0710 H
10x1019.325.81454ME 1010 H
19x1026.434.02596ME 1910 H
24x1029.236.82994ME 2410 H
30x1032.239.83579ME 3010 H