series FFj U

0.6/1kV
Cu 1 up to 300 mm²
TPE/TPU
Heavy Duty

These cables are required for industrial heavy use (Heavy Duty) such as drilling equipment and mining in general, combining high strength and flexibility. The materials used for its production provide suitable protection against chemical products, harsh environment, tear and minor.

Features

  • Temperature rating: 90ºC (dry environments), 75ºC (wet environments)

  • Voltage rating: 600/1000V AC, maximum 1200V AC / 1500V DC

  • Construction requirements: As per IEC 60502-1

  • Conductor requirements: As per IRAM NM 280 – IEC 60228

  • Conductor: Annealed electrolytic copper - Flexible stranding class 5

  • Insulation: TPE (thermoplastic rubber)

  • Sheath: Polyurethane UV and chemicals resistant

  • Fire requirements: As per IEC 60332-1

  • Outdoors requirements: As per UL 2556 (UV rays)

  • Flexing tests: Mercosur standards NM 247-2 for 300000 simple cycles

Flame retardant

Flame retardant

High flexibility

High flexibility

High sliding

High sliding

UV resistant

UV resistant

Tear and impacts

Tear and impacts

Drilling ring equipment

Drilling ring equipment

Harsh environment

Harsh environment

Identification

Standard
Sheath Conductors
3 Conductors
4 Conductors
5 Conductors

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of colour armour.

ELECTRICAL CHARACTERISTICS

Resistances, reactance and intensity of admissible currents

Nominal cross-section sq (mm²) Electrical resistance at 90ºC in A.C. Ohm/km Inductive reactance at 50hz (Ohm/Km) Current-carrying capacity in free air (1) Current-carrying capacity in earth (2)
Multipolares 3x (3) Ampere 3x (3) Ampere
124,860,112N/AN/A
1,516,960,10420,027,6
2,510,180,09727,637,1
46,310,09736,148,5
64,210,09146,660,8
102,440,08464,682,7
161,540,08086,5107,4
250,9950,080109,3140,6
350,7070,078136,8168,2
500,4930,077166,3198,6
700,3480,074212,8243,2
950,2640,074257,5292,6
1200,2070,072299,3333,5
1500,1660,072344,9373,4
1850,1370,072394,3424,7
2400,1050,072464,6493,1
3000,08530,071536,8558,6

DIMENSIONS & WEIGHT

Cable formation N° Cond. x cross-section (mm²) External diameter mm Weight kg/km Code
3x19.195FFj 0310 UNe
3x1.59.7114FFj 0315 UNe
3x2.510.6151FFj 0325 UNe
3x412.7225FFj 0340 UNe
3x613.9293FFj 0360 UNe
3x1015.9431FFj 3100 UNe
3x1620.1735FFj 3160 UNe
3x2523.71079FFj 3250 UNe
3x3526.21412FFj 3350 UNe
3x5030.11938FFj 3500 UNe
3x7034.52644FFj 3700 UNe
3x9538.73386FFj 3950 UNe
3x12043.14372FFj 31200 UNe
3x15049.25510FFj 31500 UNe
3x18554.46756FFj 31850 UNe
3x24061.28777FFj 32400 UNe
3x30069.310953FFj 33000 UNe
4x19.9113FFj 0410 UNe
4x1.510.5137FFj 0415 UNe
4x2.511.6184FFj 0425 UNe
4x413.9277FFj 0440 UNe
4x615.2363FFj 0460 UNe
4x1017.4540FFj 4100 UNe
4x1621.9906FFj 4160 UNe
3x25+1x1624.91230FFj 2516 UNe
3x35+1x1627.01547FFj 3516 UNe
3x50+1x2531.52165FFj 5025 UNe
3x70+1x3535.82941FFj 7035 UNe
3x95+1x5040.73832FFj 9550 UNe
3x120+1x7045.85033FFj 12070 UNe
3x150+1x7050.76062FFj 15070 UNe
3x185+1x9556.07466FFj 18595 UNe
3x240+1x12063.29739FFj 240120 UNe
3x300+1x15071.612141FFj 300150 UNe
5x110.7135FFj 0510 UNe
5x1.511.4165FFj 0515 UNe
5x2.512.6223FFj 0525 UNe
5x415.1338FFj 0540 UNe
5x616.6446FFj 0560 UNe
5x1019.1666FFj 5100 UNe
5x1623.91104FFj 5160 UNe
5x2528.31614FFj 5250 UNe
5x3531.62145FFj 5350 UNe
5x5037.43020FFj 5500 UNe
5x7042.04064FFj 5700 UNe
5x9547.85278FFj 5950 UNe
5x12053.36831FFj 51200 UNe
5x15060.88569FFj 51500 UNe
5x18567.210504FFj 51850 UNe