Marlew

series EC

500 Volt
Cu 0.35 up to 1.5 mm²
Double Shielding
VDE812

Suitable for data, and digital signal transmission; equipped with enhanced protection against electromagnetic disturbances. Installed in conduits, trays, cable ladders, buried in a trench or in ducts.

Features

  • Temperature rating: 80°C

  • Voltage rating:: 500 Volt

  • Construction requirements: As per VDE0812

  • Conductor requirements: As per IEC 60228 / IRAM NM 280

  • Conductor: Tinned annealed electrolytic copper, 7-wire stranding

  • Insulation: PVC

  • Shield: Aluminium-polyester tape wrap (100% coverage) plus tinned-copper braid (80% coverage)

  • Sheath: Flame retardant PVC

  • Fire requirements: As per IEC 60332-1 / IRAM NM IEC 60332-1

Electromagnetic interference protection

Electromagnetic interference protection

Double shielding

Double shielding

Flame retardant

Flame retardant

Computer systems

Computer systems

Identification

Standard
Sheath Conductors
2 Conductors
3 Conductors
4 Conductors
5 Conductors
6 Conductors or more numbered

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering can be used upon request.

ELECTRICAL CHARACTERISTICS

Nominal cross-section sq mm² Electrical resistance at 20ºC in C.C Ohm/km Velocity of propagation Mutual capacitance
VP (%) pF/m pF/ft
0.3559.9459730
0.5040.110231.5
0.7524.811034
1.0018.211736
1.5012.211636

pF/m: Mutual Capacitance between conductors of the same pair, expressed in picofarad per meter. pF/ft: Mutual Capacitance between conductors of the same pair, expressed in picofarad per feet.

DIMENSIONS & WEIGHT

Cantidad de conductores 0,35 mm² 0,50 mm²
Diameter mm Weight kg/km Code Mat Number Diameter mm Weight kg/km Code Mat Number
25,136EC 2x0.358410009105,644EC 2x0.5841000920
35,342EC 3x0.358410009605,953EC 3x0.5841000970
45,750EC 4x0.358410010106,363EC 4x0.5841001020
56,361EC 5x0.358410010607,076EC 5x0.5841001070
76,874EC 7x0.358410011107,797EC 7x0.5841001120
128,8119EC 12x0.358410011609,9152EC 12x0.5841001170
1910,1164EC 19x0.3584100121011,3212EC 19x0.5841001220
2411,5200EC 24x0.3584100126013,4280EC 24x0.5841001270

Number of conductors 0,75 mm² 1,00 mm²
Diameter mm Weight kg/km Code Mat Number Diameter mm Weight kg/km Code Mat Number
26,255EC 2x0.758410009306,663EC 2x1841000940
36,567EC 3x0.758410009806,978EC 3x1841000990
47,080EC 4x0.758410010307,698EC 4x1841001040
57,898EC 5x0.758410010808,2115EC 5x1841001090
78,5125EC 7x0.758410011309,1149EC 7x1841001140
1210,7192EC 12x0.7584100118011,7237EC 12x1841001190
1912,8292EC 19x0.7584100123013,7354EC 19x1841001240
2414,9367EC 24x0.7584100128016,1451EC 24x1841001290

Number of conductors 1,50 mm²
Diameter mm Weight kg/km Code Mat Number
27,888EC 2x1.5841000950
38,2110EC 3x1.5841001000
48,8134EC 4x1.5841001050
59,6159EC 5x1.5841001100
710,6208EC 7x1.5841001150
1214,0349EC 12x1.5841001200
1916,6518EC 19x1.5841001250
2419,3661EC 24x1.5841001300