Marlew

series CY

600 Volt
Cu 14 up to 10 AWG
Double insulation
UL 1277

Control, signalling, measuring and protective equipment; electric controls of industrial installations. Installed in aerial trays, gutters or conduits, under roof or ladder under roof, buried in ducts or directly buried. Manufactured in compliance with the National Electrical Code ANSI/NFPA 70 of the US and the National Electrical Code NOM-001 SEDE, Mexico.

Features

  • Temperature rating: 90ºC (operating), 160ºC (short circuit)

  • Voltage rating: 600V AC

  • Construction requirements: As per UL 1277

  • Conductor requirements: As per ASTM B8

  • Conductor: Annealed electrolytic copper; class B

  • Primary insulation: Special PVC compound

  • Secondary insulation: THHN (Nylon)

  • Sheath: PVC, fire-retardant

  • Fire requirements: As per UL 1685

  • Outdoors requirements: As per UL 2556 (UV rays)

  • NEC code (NFPA 70): Art 336 - Art 501 classified areas Cl 1 Div 2 and Cl 2 Div 2

Fire-retardant

Fire-retardant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Industrial applications

Industrial applications

Tray cable

Tray cable

Wet locations

Wet locations

Identification

Standard
Sheath Conductors
Multiconductor alphanumeric identification

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Gauge AWG Electrical resistance at 20°C in C.C.  (Ohm/km) Electrical resistance at 90°C in C.A. at 60Hz (Ohm/km) Current-carrying capacity (1)
2x 4x 7x 10x 19x 30x 48x
148.7911.21252017.512.512.511.38.8
125.547.06302421151513.510.5
103.484.4440322820201814

(1) Current-carrying capacity of cables with up to three conductors, installed in ducts or directly buried, up to an ambient temperature of 30ºC, according to chart 310.15 (B)(16) of the NFPA 70. As from four-conductors, we’ve additionally applied the correction factor for more than three conductors from the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable Formation N° Cond. x gauge AWG External diameter mm Weight kg/km Code Mat Number Previous Code
2 x 147.9101CY 2x14820047010CY 0214
3 x 148.4124CY 3x14820047020CY 0314
4 x 149.1152CY 4x14820047030CY 0414
5 x 149.9180CY 5x14820047040CY 0514
7 x 1410.8235CY 7x14820047050CY 0714
10 x 1414.2332CY 10x14820047060CY 1014
12 x 1414.6383CY 12x14820047070CY 1214
14 x 1415.7439CY 14x14820047080CY 1414
19 x 1417.3575CY 19x14820047100CY 1914
24 x 1419.9714CY 24x14820047120CY 2414
30 x 1422.3921CY 30x14820047140CY 3014
37 x 1424.01112CY 37x14820047160CY 3714
48 x 1427.01410CY 48x14820047170CY 4814
2 x 128.9138CY 2x12820047180CY 0212
3 x 129.4172CY 3x12820047190CY 0312
4 x 1210.3213CY 4x12820047200CY 0412
5 x 1211.2254CY 5x12820047210CY 0512
7 x 1212.2335CY 7x12820047220CY 0712
10 x 1216.1470CY 10x12820047230CY 1012
12 x 1216.6547CY 12x12820047240CY 1212
14 x 1217.8629CY 14x12820047250CY 1412
19 x 1219.7829CY 19x12820047270CY 1912
24 x 1223.71089CY 24x12820047290CY 2412
30 x 1225.41326CY 30x12820047310CY 3012
37 x 1227.41610CY 37x12820047330CY 3712
48 x 1230.82051CY 48x12820047340CY 4812
2 x 1010.6205CY 2x10820047350CY 0210
3 x 1011.3259CY 3x10820047360CY 0310
4 x 1012.4322CY 4x10820047370CY 0410
5 x 1014.3411CY 5x10820047380CY 0510
7 x 1015.6540CY 7x10820047390CY 0710
10 x 1019.5412CY 10x10820047400CY 1010
12 x 1020.1833CY 12x10820047410CY 1210
14 x 1022.61012CY 14x10820047420CY 1410
19 x 1025.11333CY 19x10820047440CY 1910
24 x 1028.91664CY 24x10820047460CY 2410
30 x 1031.02037CY 30x10820047480CY 3010
37 x 1033.52482CY 37x10820047500CY 3710
48 x 1037.83174CY 48x10820047510CY 4810