series BSPPower supply of submersible pumps used in potable-water wells under 40ºC, in flooded areas, to evacuate swimming pools, to filter or clean the water in tanks or similar sites. For Alternating Current (50/60Hz), for single-phase systems (220/110V), three-phase systems (380/190V) and systems with voltages up to 1kV. For Direct Current, used in systems with voltages up to 1.5kV
| Estandar | ||
|---|---|---|
| Cubierta | Conductores | |
| 3 Conductors | ![]() | ![]() ![]() ![]() |
| 4 Conductors | ![]() | ![]() ![]() ![]() ![]() |
The information provided corresponds to the standard version, and different alternatives of insulation and / or covering materials can be used upon request.
| Nominal cross-section (mm²) | Electrical resistance at 20°C in C.C. (Ohm/km) | Electrical resistance at 90°C en C.C. (Ohm/km) | Inductive reactance at 50Hz (Ohm/Km) | Current-carrying capacity of cables in free air at 40°C as per IEC 364-5-523. (1) (Amper) |
|---|---|---|---|---|
| | |||
| | |||
| 1.5 | 13.3 | 16.96 | 0.126 | 19 |
| 2.5 | 7.98 | 10.18 | 0.118 | 26 |
| 4 | 4.95 | 6.31 | 0.112 | 34 |
| 6 | 3.3 | 4.21 | 0.105 | 45 |
| 10 | 1.91 | 2.44 | 0.103 | 62 |
| 16 | 1.21 | 1.54 | 0.098 | 83 |
| 25 | 0.78 | 0.99 | 0.097 | 122 |
| 35 | 0.554 | 0.707 | 0.095 | 152 |
| 50 | 0.386 | 0.493 | 0.094 | 187 |
| 70 | 0.272 | 0.348 | 0.091 | 241 |
| 95 | 0.206 | 0.264 | 0.090 | 295 |
| 120 (2) | 0.161 | 0.207 | 0.088 | 346 |
| 150 (2) | 0.129 | 0.167 | 0.088 | 381 |
(1) Cables installed in air at 40ºC according to IEC 364-5-523. These values can be taken as a reference for cables submerged or in contact with water in wells up to 100 meters deep. When it comes to depths greater than 100 meters, each particular case must be studied as to how the cable will be affected by the environment due to temperatures, liquids and other conditions that can impair the cable's conduction. For more information on allowable intensity values and types of installation, we suggest consulting the IEC 364-5-523 standard. (2) These sections are outside the scope of IRAM 63007.
| Cable formation No. Cond. x section (mm²) | External height mm | Outer width mm | Weight kg/km | Bending radius mm | Code | Mat Number |
|---|---|---|---|---|---|---|
| 3 x 1.5 | 5,9 | 12,8 | 113 | 41 | BSP 3 x 1.5 | 830150605 |
| 3 x 2.5 | 6,5 | 14,3 | 153 | 46 | BSP 3 x 2.5 | 830150615 |
| 3 x 4 | 7,0 | 15,9 | 203 | 49 | BSP 3 x 4 | 830150625 |
| 3 x 6 | 7,6 | 17,5 | 266 | 53 | BSP 3 x 6 | 830150635 |
| 3 x 10 | 9,2 | 21,9 | 430 | 64 | BSP 3 x 10 | 830150645 |
| 3 x 16 | 10,3 | 25,0 | 609 | 72 | BSP 3 x 16 | 830150655 |
| 3 x 25 | 12,2 | 30,1 | 911 | 85 | BSP 3 x 25 | 830150665 |
| 3 x 35 | 13,3 | 33,6 | 1.204 | 93 | BSP 3 x 35 | 830150675 |
| 3 x 50 | 15,5 | 39,4 | 1.683 | 109 | BSP 3 x 50 | 830150685 |
| 3 x 70 | 17,4 | 44,6 | 2.300 | 122 | BSP 3 x 70 | 830150695 |
| 3 x 95 | 19,4 | 50,3 | 2.973 | 136 | BSP 3 x 95 | 830150705 |
| 3 x 120 | 21,3 | 55,6 | 3.763 | 149 | BSP 3 x 120 | 830150706 |
| 3 x 150 | 24,3 | 64,2 | 4.726 | 170 | BSP 3x 150 | 830150707 |
| 3 x 1.5 + 1 x1.5 | 6,1 | 16,5 | 153 | 43 | BSP 3X1.5+PE1.5 | 830150710 |
| 3 x 2.5 + 1 x 2.5 | 6,5 | 18,2 | 200 | 46 | BSP 3X2.5+PE2.5 | 830150720 |
| 3 x 4 + 1 x 4 | 7,0 | 20,3 | 267 | 49 | BSP 3X4+PE4 | 830150730 |
| 3 x 6 + 1 x 6 | 7,8 | 22,7 | 359 | 55 | BSP 3X6+PE6 | 830150740 |
| 3 x 10 + 1 x 10 | 9,4 | 28,4 | 580 | 67 | BSP 3X10+PE10 | 830150750 |
| 3 x 16 + 1 x 16 | 10,3 | 32,3 | 809 | 74 | BSP 3X16+PE16 | 830150760 |
| 3 x 25 + 1 x 25 | 12,4 | 39,3 | 1.224 | 88 | BSP 3X25+PE25 | 830150770 |
| 3 x 35 + 1 x 35 | 13,7 | 44,1 | 1.633 | 96 | BSP 3X35+PE35 | 830150780 |
| 3 x 50 + 1 x 50 | 15,7 | 51,6 | 2.259 | 110 | BSP 3X50+PE50 | 830150790 |
| 3 x 70 + 1 x 70 | 17,6 | 58,4 | 3.086 | 125 | BSP 3X70+PE70 | 830150800 |
| 3 x 95 + 1 x 95 | 19,8 | 66,2 | 4.009 | 145 | BSP 3X95+PE95 | 830150810 |
| 3 x 120 + 1 x 120 | 21,7 | 73,2 | 5.070 | 156 | BSP 3X120+PE120 | 830150820 |