series AI

300 Volt
Cu 20 up to 12 AWG
PVC 105°C / PVC
UL 1424 FPL

Electronic instrumentation, analog and digital signal circuits (4-20mA). Specially designed for fire detection warning alarms Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts.

Features

  • Temperature rating: 105°C

  • Voltage rating: 300 Volt

  • Construction requirements: As per UL 1424 type FPL

  • Conductor requirements: As per ASTM B8 Class B

  • Conductor: Annealed electrolytic copper, 7-wire stranding

  • Insulation: PVC

  • Lay length: 50mm (20 twists/m)

  • Unshielded pair: Polyester tape helical wrap

  • Shield: Aluminium-polyester tape wrap plus tinned-copper braid

  • Sheath: PVC (Low Smoke Zero Halogen - Halogen Free Flame Retardant) flame retardant, sunlight, and oil resistant

  • Fire requirements: As per UL 1685

  • Hydrocarbons requirements: As per NFC 32-200 – ASTM D 1239

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • NEC code (NFPA 70): Art. 760 FPL

Fire-retardant

Fire-retardant

Hydrocarbon resistant

Hydrocarbon resistant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Special marking

Special marking

Tray cable

Tray cable

Identification

Standard
Sheath Conductors
Pair
Triad
Quad

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering materials can be used upon request.

ELECTRICAL CHARACTERISTICS

Conductor’s gauge Cable structure Shield type Electrical resistance in D.C. at 20°C Mutual capacitance between conductors Characteristic impedance Mutual inductance
AWG ohm/km pf/m ohm microH/km
20Pair / triad / quadUnshielded35.789876588
Shielded18041
18Pair / triad / quadUnshielded22.788588641
Shielded16550
16Pair / triad / quadUnshielded14.2511266544
Shielded21035
14Pair / triad / quadUnshielded8.9410968553
Shielded20337
12Pair / triad / quadUnshielded5.6312162522
Shielded22833

pF/m = Mutual Capacitance between conductors, expressed in picofarad per meter / uH/km = Mutual inductance between conductors, expressed in microhenry per kilometer

DIMENSIONS & WEIGHT

Pair

AWG Shield Drain wire External diameter mm Weight kg/km Code
20----4.930AI 0500
Yes225.034AI 5000
18----5.640AI 0510
Yes205.746AI 5100
16----6.253AI 0520
Yes186.362AI 5200
14----7.782AI 0530
Yes187.891AI 5300
12----8.7112AI 0580
Yes188.8121AI 5800

Triad - Shielded

AWG Drain wire External diameter mm Weight kg/km Code
20225.342AI 6000
18206.058AI 6100
16186.779AI 6200
14188.3119AI 6300
12189.3162AI 6800

Quad - Shielded

AWG Drain wire External diameter mm Weight kg/km Code
20225.750AI 9000
18206.570AI 9100
16187.5102AI 9200
14189.0147AI 9300
121810.7216AI 9800