series AF

300 Volt
Cu 20 up to 12 AWG
Insulation (MICA+LSZH)
UL 13 PLTC

Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and monitoring equipment. Alarm signal monitoring. Use in closed environments with a high concentration of people (airports, hospitals, trains, cinemas, shopping centers, tunnels) and in control rooms with electronic equipment sensitive to the exposure of corrosive gases. Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts.

Features

  • Temperature rating: 90°C

  • Voltage rating: 300 Volt

  • Construction requirements: As per UL 13 type PLTC - UL 2250 type ITC

  • Conductor requirements: As per ASTM B8 Class B

  • Conductor: Annealed electrolytic copper, 7-wire stranding

  • Insulation: MICA tape + LSZH-HFFR layer (Low Smoke Zero Halogen - Halogen Free Flame Retardant)

  • Lay length: 50mm (20 twists/m)

  • Shield: Aluminium-polyester tape wrap plus tinned-copper braid

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant) flame retardant, sunlight, and oil resistant

  • Fire requirements: As per UL 1685 – IEC 60332-3-24

  • Fire-resistance requirements: IEC 60331-23 (70000 BTU-750°C applied for 90 minutes)

  • Standard for halogen absence and corrosive gases: As per IEC 60754-1/2

  • Smoke transparency requirements: As per IEC 61034-1/2

  • Toxicity standard: As per NES 713 – CEI 20.37

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (rayos UV)

  • Water behaviour requirements: Suitable AD7 (Occasional water submersion)

  • NEC code (NFPA 70): Art. 725 PLTC – Art. 727 ITC – Art. 800 CM – Art. 501 classified locations CL1 Div.2 y Cl2 Div.2

Fire-retardant

Fire-retardant

Fire-resistant

Fire-resistant

Halogen free

Halogen free

Low smoke

Low smoke

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Identification

Standard Intrinsically safe
Sheath Conductors Sheath Conductors
Pair
Triad
Quad
Multipair+N+N
Multiriad+N+N

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering materials can be used upon request. Instrumentation cables can be manufactured under a different standard, such as: NBR 10300, EN 50288-7 or ICEA S 73-532, complying with other electrical and dimensional parameters.

ELECTRICAL CHARACTERISTICS

Conductor’s gauge Cable structure Shield type Electrical resistance in D.C. at 20°C Mutual capacitance between conductors Characteristic impedance Mutual inductance
AWG ohm/km pf/m ohm microH/km
20Pair / triad / quadUnshielded35.7874102703
Shielded13157
Multipair / multitriadOverall Shield8786
Individual and overall shield13157
18Pair / triad / quadUnshielded22.7866114755
Shielded11764
Multipair / multitriadOverall Shield7995
Individual and overall shield11764
16Pair / triad / quadUnshielded14.258885628
Shielded16047
Multipair / multitriadOverall Shield10174
Individual and overall shield16047
14Pair / triad / quadUnshielded8.949083620
Shielded16446
Multipair / multitriadOverall Shield10373
Individual and overall shield16446
12Pair / triad / quadUnshielded5.6310175580
Shielded18541

pF/m = Mutual Capacitance between conductors, expressed in picofarad per meter / uH/km = Mutual inductance between conductors, expressed in microhenry per kilometer

DIMENSIONS & WEIGHT

Pair

AWG Shield Drain wire External diameter mm Weight kg/km Code
20----6.241AF 0500
Yes226.345AF 5000
18----7.257AF 0510
Yes207.363AF 5100
16----7.770AF 0520
Yes187.879AF 5200
14----9.097AF 0530
Yes189.1106AF 5300
12----10.4139AF 0580
Yes1810.5148AF 5800

Triad - Shielded

AWG Drain wire External diameter mm Weight kg/km Code
20226.756AF 6000
18207.779AF 6100
16188.399AF 6200
141810.2150AF 6300
121811.2194AF 6800

Quad - Shielded

AWG Drain wire External diameter mm Weight kg/km Code
20227.472AF 9000
18208.495AF 9100
16189.0121AF 9200
141811.1185AF 9300
121812.2242AF 9800

Multipairs

Number of pairs AWG Overal shield Individual and overall shield
External diameter mm Weight kg/km Code External diameter mm Weight kg/km Code
2208.681AF 70028.892AF 7402
310.8120AF 700311.5139AF 7403
411.7150AF 700412.5174AF 7404
613.9200AF 700614.9235AF 7406
815.0244AF 700816.6308AF 7408
1218.8359AF 701220.2426AF 7412
1620.8447AF 701622.9561AF 7416
2023.6565AF 702025.3674AF 7420
2426.2660AF 702428.2791AF 7424
3630.0910AF 703632.81138AF 7436
2189.5106AF 710210.2132AF 7502
312.1158AF 710313.0183AF 7503
413.3196AF 710414.2229AF 7504
616.3285AF 710617.5333AF 7506
817.6348AF 710818.9410AF 7508
1221.4483AF 711223.6603AF 7512
1624.3637AF 711626.1757AF 7516
2026.9766AF 712029.0915AF 7520
2430.0899AF 712432.81115AF 7524
3634.91296AF 713637.61559AF 7536
21610.6141AF 720210.8162AF 7602
313.1194AF 720314.0229AF 7603
414.3244AF 720415.9307AF 7604
617.6356AF 720618.9422AF 7606
819.1440AF 720820.5527AF 7608
1223.8647AF 721225.6777AF 7612
1626.4817AF 721628.4986AF 7616
2029.3989AF 722032.11236AF 7620
2433.21204AF 722435.71457AF 7624
3638.01692AF 723641.52113AF 7636
21412.2194AF 730212.4215AF 7702
316.1292AF 730317.2331AF 7703
417.6367AF 730418.9416AF 7704
621.1509AF 730623.2609AF 7706
823.4666AF 730825.1761AF 7708
1228.5943AF 731230.71081AF 7712
1632.31240AF 731634.81423AF 7716
2035.91506AF 732038.71733AF 7720
2440.01779AF 7324437.02102AF 7724
3646.52587AF 733650.22986AF 7736

Multiriads

Number of triads AWG Overal shield Individual and overall shield
External diameter mm Weight kg/km Code External diameter mm Weight kg/km Code
22012.2130AF 800212.4141AF 8402
313.0162AF 800313.2178AF 8403
414.3202AF 800414.5224AF 8404
617.5295AF 800617.8327AF 8406
819.0361AF 800819.3402AF 8408
1223.6529AF 801224.0591AF 8412
1626.2661AF 801626.7743AF 8416
2029.1794AF 802029.6896AF 8420
2433.0971AF 802433.61094AF 8424
3637.81344AF 803638.51526AF 8436
21813.8169AF 810214.0184AF 8502
314.7214AF 810315.0236AF 8503
416.7288AF 810416.9317AF 8504
619.9392AF 810620.2435AF 8506
821.6485AF 810822.0541AF 8508
1227.0713AF 811227.4798AF 8512
1630.0899AF 811630.51011AF 8516
2033.81127AF 812034.41267AF 8520
2437.81325AF 812438.41493AF 8524
3643.91911AF 813644.62161AF 8536
21614.8206AF 820215.0226AF 8602
316.3286AF 820316.5317AF 8603
417.9358AF 820418.1398AF 8604
621.4495AF 820621.7555AF 8606
823.8648AF 820824.1728AF 8608
1229.0914AF 821229.51033AF 8612
1632.81201AF 821633.31360AF 8616
2036.51457AF 822037.01655AF 8620
2440.81720AF 822441.92008AF 8624
3647.42497AF 823648.12851AF 8636
21418.3310AF 830218.5332AF 8702
319.6406AF 830319.8438AF 8703
421.5512AF 830421.8555AF 8704
626.5751AF 830626.8815AF 8706
828.7944AF 830829.11029AF 8708
1235.81390AF 831236.21517AF 8712
1639.91777AF 831640.41945AF 8716
2045.02224AF 832045.52433AF 8720
2450.32630AF 832450.92881AF 8724
3657.93752AF 833658.64126AF 8736