Marlew

series SWZ

300 Volt
LSZH 90°C / LSZH
UL 1424 FPLR
Cu 20 up to 16 AWG

Trays, stairs, conduits and buried. Vertical lines in shafts or tunnels that exceed more than 1 floor (Elevators, Forklifts). In closed places with a high concentrations of people. Indoor and Outdoor use. Fire detection systems and alarm notification (visual and sound), flow and control of automatic water sprinkler systems. Control of building security functions, sensors in elevators, door opening, fan output and control of smoke and smoke protection systems. firewall, intercom systems and public address system.

Features

  • Temperature rating: 90°C

  • Voltage rating: 300 Volt

  • Construction requirements: As per UL 1424 type FPLR

  • Conductor requirements: As per ASTM B3

  • Conductor: Single Annealed Electrolytic Copper Wire

  • Insulation: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame  Retardant)

  • Lay length: 50mm (20 twists/m)

  • Shielded Pair: Aluminium-polyester tape wrap plus tinned-copper braid

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant) flame retardant, sunlight, and oil resistant

  • Fire requirements: As per UL 1666 - UL 1685

  • Standard for halogen absence and corrosive gases: As per IEC 60754-1/2

  • Smoke transparency requirements: As per IEC 61034-1/2

  • Toxicity standard: As per NES 713 – CEI 20.37

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • Water behaviour requirements: Suitable AD7 (Occasional water submersion)

  • NEC code (NFPA 70): Art. 760 FPLR

Fire-retardant

Fire-retardant

Halogen free

Halogen free

Low smoke

Low smoke

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Alarm and fire

Alarm and fire

Identification

Standard
Sheath Conductors
Pair

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering materials can be used upon request.

ELECTRICAL AND DIMENSIONAL CHARACTERISTICS

Conductor’s gauge Cable structure Code Electrical resistance in D.C. at 20°C Mutual capacitance between conductors Characteristic impedance Mutual inductance External Diameter Weight
AWG ohm/km pf/m ohm microH/km mm kg/km
20Simple PairSWZ 1P2037.86144525032.914.6
Shielded PairSWZ-O 1P2027930317.3
18Simple PairSWZ 1P1822.26131575263.722.6
Shielded PairSWZ-O 1P18251333.825.2
16Simple PairSWZ 1P1614.04147514994.232.8
Shielded PairSWZ-O 1P16285304.335.6

pF/m = Mutual Capacitance between conductors, expressed in picofarad per meter / uH/km = Mutual inductance between conductors, expressed in microhenry per kilometer

PACKAGING FORMAT - REELEX BOX

Code Mat Number Mts Weight per Box (kg) Width (cm) Length (cm) Height (cm)
Cj305 | SWZ 1P208600010023054.827,534,538
Cj305 | SWZ-O 1P208600010033055.627,534,538
Cj305 | SWZ 1P188600010043057.227,534,538
Cj305 | SWZ-O 1P18860001005305827,534,538
Cj305 | SWZ 1P1686000100630510.327,534,538
Cj305 | SWZ-O 1P1686000100730511.227,534,538
Cj500 | SWZ 1P208600010105007.627,534,538
Cj500 | SWZ-O 1P20860001011500927,534,538
Cj500 | SWZ 1P1886000101250011.629.744.542.5
Cj500 | SWZ-O 1P1886000101350012.929.744.542.5
Cj500 | SWZ 1P1686000101450016.729.744.542.5
Cj500 | SWZ-O 1P1686000101550018.129.744.542.5