series RPC

0.6/1kV
Flexible Cu 1 up to 300mm²
Insulation (MICA+XLPE)
Includes PE conductor

For fixed power distribution networks for alternating current (50/60Hz), for single-phase systems (220/110V), three-phase systems (380/190V) and systems with voltages up to 1kV. For Direct Current, used in systems with voltages up to 1.5kV Use in closed environments with a high concentration of people (airports, hospitals, trains, cinemas, shopping centers, tunnels) and in control rooms with electronic equipment sensitive to the exposure of corrosive gases. Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts.

Features

  • Temperature ratings: 90°C (Operating) – 130°C (Overload) – 250°C (Short-Circuit)

  • Voltage rating: 600/1000 Volt A.C. – 1200 Volt A.C. (Max) – 1500 Volt D.C.

  • Construction requirements: IRAM 62266 – IEC 60502-1

  • Conductor requirements: IRAM NM 280 – IEC 60228

  • Conductor: Annealed electrolytic copper - Flexible stranding class 5

  • Insulation: Mica tape + XLPE (Cross-Linked Polyethylene)

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant), flame retardant, sunlight, and oil resistant

  • Fire requirements: As per IEC 60332-3-24

  • Fire resistance standards: As per IEC 60331-21 (70000 BTU-750°C applied for 90 minutes)

  • Standard for Halogen absence and corrosive gases: IEC 60754-1/2

  • Smoke transparency requirements: IEC 61034-1/2

  • Toxicity standard: NES 713 – CEI 20.37

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • Water behaviour requirements: Suitable for AD7 (Occasional water submersion)

Fire-retardant

Fire-retardant

Fire-resistant

Fire-resistant

Halogen free

Halogen free

Low smoke

Low smoke

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Identification

Standard
Sheath Conductors
3 Conductors
4 Conductors
5 Conductors

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version. Special design can be manufactured to comply with reinforced circuit integrity, complying with other standards such as IEC 60331-1/2, EN 50200 or BS 6387.

ELECTRICAL CHARACTERISTICS

Resistances, reactance and intensity of admissible currents

Nominal cross-section (mm²) Electrical resistance in D.C. at 20°C (Ohm/km) Electrical resistance in C.C. at 90°C (Ohm/km) Inductive reactance at 50Hz (Ohm/Km) Current-carrying capacity of cables in free air at 40°C as per IEC 364-5-523. Formations in cable ladder or perforated cable trays (Ampere) Current-carrying capacity of cables directly buried at 25°C soil temperature and soil thermal resistance of 1 km/W as per IEC 364-5-523 (Ampere)
Multiconductor (1) 4 Conductors (2) 2 Conductors (3) Multiconductor (4) 2 Conductors (3) Multiconductor (4)
119.524.860.1190.126--------
1.513.316.960.1110.11823203228
2.57.9810.180.1030.11031284437
44.956.310.0970.10543365748
63.34.210.0900.09854477261
101.912.440.0840.09174659783
161.211.540.0820.08910086129107
250.780.990.0790.087128109166141
350.5540.7070.0770.084160137200168
500.3860.4930.0760.083195166238199
700.2720.3480.0740.082250213292243
950.2060.2640.0720.079304257351293
1200.1610.2070.0720.079354299399333
1500.1290.1670.0710.079409345448373
1850.1060.1380.0720.079468394508425
2400.08010.1060.0710.078554465592493
3000.06410.08600.0700.077640537669559

(1) Calculation of Inductive reactance valid for three-conductor and five-conductor cables. (2) Calculation of Inductive reactance valid for four-conductor cables. (3) The values of current-carrying capacity informed, correspond to three conductor cable (two-conductor + protection conductor). (4) The values of current-carrying capacity informed, correspond to four-conductor, five-conductor.

DIMENSIONS & WEIGHT

Cable Formation, N° Cond. x cross-section (mm²) External diameter mm Weight kg/km Code
3 x 19.9124.0RPC 0310
3 x 1.510.6146RPC 0315
3 x 2.511.6187RPC 0325
3 x 412.6244RPC 0340
3 x 613.9317RPC 0360
3 x 1016.1472RPC 3100
3 x 1621.3799.0RPC 3160
3 x 2524.21122.0RPC 3250
3 x 3526.41448.0RPC 3350
3 x 50301957RPC 3500
3 x 7035.32715RPC 3700
3 x 9539.83475RPC 3950
3 x 12043.74371.0RPC 31200
3 x 15049.85469RPC 31500
3 x 18553.96545RPC 31850
3 x 24061.68571RPC 32400
3 x 30068.710671.0RPC 33000
4 x 110.8145RPC 0410
4 x 1.511.5171RPC 0415
4 x 2.512.6222RPC 0425
4 x 413.8295RPC 0440
4 x 615.3385RPC 0460
4 x 1017.7581.0RPC 4100
4 x 1623.2974.0RPC 4160
3 x 25 + 1 x 1625.61279.0RPC 2516
3 x 35 + 1 x 1627.51590RPC 3516
3 x 50 + 1 x 2531.32174RPC 5025
3 x 70 + 1 x 3536.52999RPC 7035
3 x 95 + 1 x 5041.53901.0RPC 9550
3 x 120 + 1 x 7046.14992RPC 12070
3 x 150 + 1 x 7051.26004RPC 15070
3 x 185 + 1 x 9556.07297RPC 18595
3 x 240 + 1 x 12063.79512.0RPC 240120
3 x 300 + 1 x 15071.211832RPC 300150
5 x 111.7165RPC 0510
5 x 1.512.5198RPC 0515
5 x 2.513.7260RPC 0525
5 x 415347RPC 0540
5 x 616.7457.0RPC 0560
5 x 1019.4694.0RPC 5100
5 x 16215.21156.0RPC 5160
5 x 2528.91650RPC 5250
5 x 3531.62159RPC 5350
5 x 5036.93011RPC 5500
5 x 70434131.0RPC 5700
5 x 9549.25364RPC 5950
5 x 12053.96767RPC 51200
5 x 15061.08367RPC 51500
5 x 18566.610129.0RPC 51850
5 x 24075.713174RPC 52400
5 x 30084.916481RPC 53000