series GX

Corrugated copper shielding

0.6/1kV
Flexible Cu 1 up to 4mm²
XLPE 90°C / PVC
Electromagnetic protection

Control, signalling, measuring and protective equipment, electric controls of high voltage substations (SSEE), its shielding allows adequate filtering of electromagnetic interference at frequencies up to 1 MHz. Installed in aerial trays, gutters or conduits, under roof or ladder under roof, buried in ducts or directly buried.

Features

  • Temperature rating: 90ºC (operating), 130ºC (overload), 250ºC (short circuit)

  • Voltage rating: 600/1000V AC, maximum 1200V AC / 1500V DC

  • Construction requirements: As per IRAM 2178-1 – IEC 60502-1

  • Conductor requirements: As per IRAM NM 280 – IEC 60228

  • Conductor: Annealed electrolytic copper; class 5 stranding

  • Insulation: XLPE (Cross-linked polyethylene)

  • Bedding: PVC

  • Shield: Corrugated copper tape longitudinal overlapping wrap

  • Sheath: PVC, fire-retardant sunlight and oils resistant

  • Fire requirements: As per IEC 60332-3-24

  • EMC requirements: Transfer impedance lower than 2 ohm/km up to 1MHz (as per IRAM 63020; HN 33-S-34)

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

Corrugated copper shield

Corrugated copper shield

Flame retardant

Flame retardant

Flexible stranded conductors

Flexible stranded conductors

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Industrial applications

Industrial applications

Identification

Standard
Sheath Conductors
Multiconductors with alpha-numerically

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering materials can be used upon request.

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Nominal cross-section sq mm² Electrical resistance at 20ºC in C.C Ohm/km Electrical resistance at 90ºC in C.A. Ohm/km Current-carrying capacity in free air. At 40°C as per IEC 364-5-523. Formations in perforated trays or ladder type. (Ampere)
2x 4x 7x 10x 19x 30x 48x
119.524.86--------------
1.513.316.96232016.111.511.510.48.1
2.57.9810.18312821.715.515.514.010.9
44.956.31433630.121.521.519.4--

As from seven-conductors, we’ve additionally applied the correction factor for more than three conductors the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable formation N° Cond. x cross-section (mm²) Diameter below shield mm External diameter mm Weight kg/km Code
2x18.714.6314GX 0210
3x18.714.6317GX 0310
4x18.714.6318GX 0410
5x18.714.6321GX 0510
7x19.715.6361GX 0710
10x111.717.6431GX 1010
12x112.218.1452GX 1210
14x113.219.1495GX 1410
19x115.221.1590GX 1910
24x116.722.6667GX 2410
30x118.724.6777GX 3010
37x120.726.6898GX 3710
48x123.229.11072GX 4810
2x1.58.714.6319GX 0215
3x1.58.714.6324GX 0315
4x1.58.714.6328GX 0415
5x1.59.715.6366GX 0515
7x1.510.216.1396GX 0715
10x1.512.718.6492GX 1015
12x1.513.719.6540GX 1215
14x1.514.220.1568GX 1415
19x1.516.722.6703GX 1915
24x1.518.224.1796GX 2415
30x1.520.226.1926GX 3015
37x1.522.228.11068GX 3715
48x1.525.231.31329GX 4815
2x2.58.714.6330GX 0225
3x2.58.714.6341GX 0325
4x2.59.715.6381GX 0425
5x2.510.716.6427GX 0525
7x2.511.717.6489GX 0725
10x2.514.220.1601GX 1025
12x2.515.221.1663GX 1225
14x2.516.222.1726GX 1425
19x2.518.724.6894GX 1925
24x2.520.726.61048GX 2425
30x2.523.229.11256GX 3025
37x2.525.731.61485GX 3725
48x2.529.5361914GX 4825
2x49.715.6380GX 0240
3x410.216.1416GX 0340
4x411.217.1469GX 0440
5x412.218.1526GX 0540
7x413.219.1610GX 0740
10x416.222.1769GX 1040
12x417.723.6876GX 1240
14x418.724.6959GX 1440
19x421.727.61211GX 1940
24x424.230.11456GX 2440
30x426.732.81751GX 3040
37x429.5362103GX 3740