Block series FX-W

Copper tape shield

0.6/1kV
Flexible Cu 1 up to 4mm²
Up to 48 Conductors
XLPE 90°C / PVC

Control, signalling, measuring and protective equipment; electric controls of industrial installations. Installed in aerial trays, gutters or conduits, under roof or ladder under roof, buried in ducts or directly buried. It provides additional electromagnetic protection.

Features

  • Temperature rating: 90ºC (operating),130ºC (overload) and 250ºC (short circuit)

  • Voltage rating: 600/1000V AC, maximum 1200V AC / 1500V DC

  • Construction requirements: As per IRAM 2178-1 – IEC 60502-1

  • Conductor requirements: As per IRAM NM 280 – IEC 60228

  • Conductor: Annealed electrolytic copper - Flexible stranding class 5

  • Insulation: XLPE (Cross-linked polyethylene)

  • Shield: Annealed copper tape helical wrap with 100% coverage and overlap

  • Sheath: PVC, fire-retardant; sunlight and oils resistant

  • Fire requirements: As per IEC 60332-1

  • Oils requirements: As per ICEA S 73-532

  • Outdoor requirements: As per UL 2556 (UV rays)

Electromagnetic interference protection

Electromagnetic interference protection

Flame retardant

Flame retardant

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Industrial applications

Industrial applications

Tray cable

Tray cable

Identification

Standard
Sheath Conductors
Multiconductors alphanumeric identification

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering materials can be used upon request.

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Nominal cross-section sq mm² Electrical resistance at 20ºC in C.C Ohm/km Electrical resistance at 90ºC in C.A. Ohm/km Current-carrying capacity in free air. At 40°C as per IEC 364-5-523. Formations in perforated trays or ladder type. (Ampere)
2x 4x 7x 10x 19x 30x 48x
119.524.86--------------
1.513.316.96232016.111.511.510.48.1
2.57.9810.18312821.715.515.514.010.9
44.956.31433630.121.521.519.4--

As from seven-conductors, we’ve additionally applied the correction factor for more than three conductors the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable Formation N° Cond. x cross-section (mm²) Diameter below shield mm External diameter mm Weight kg/km Code
5x19.012.4217FX 0510 W
7x19.813.1243FX 0710 W
10x111.614.9304FX 1010 W
12x112.515.8341FX 1210 W
14x113.416.7376FX 1410 W
19x115.218.5461FX 1910 W
24x116.820.1543FX 2410 W
30x118.621.9638FX 3010 W
37x120.423.8761FX 3710 W
48x122.926.3928FX 4810 W
3x1.59.012.4220FX 0310 W
4x1.59.012.4223FX 0415 W
5x1.59.713.1245FX 0515 W
7x1.510.613.9287FX 0715 W
10x1.512.615.9362FX 1015 W
12x1.513.616.9408FX 1215 W
14x1.514.517.8453FX 1415 W
19x1.516.519.8563FX 1915 W
24x1.518.321.6669FX 2415 W
30x1.520.223.6808FX 3015 W
37x1.522.225.6951FX 3715 W
48x1.525.028.41170FX 4815 W
2x2.59.012.4225FX 0225 W
3x2.59.112.5240FX 0325 W
4x2.510.013.3269FX 0425 W
5x2.510.914.2312FX 0525 W
7x2.511.915.2373FX 0725 W
10x2.514.117.5472FX 1025 W
12x2.515.318.6538FX 1225 W
14x2.516.319.7603FX 1425 W
19x2.518.722.0762FX 1925 W
24x2.520.724.1931FX 2425 W
30x2.522.926.31113FX 3025 W
37x2.525.328.71323FX 3725 W
48x2.528.932.71705FX 4825 W
2x49.713.0257FX 0240 W
3x410.313.6296FX 0340 W
4x411.314.6348FX 0440 W
5x412.315.7407FX 0540 W
7x413.516.8496FX 0740 W
10x416.119.4633FX 1040 W
12x417.420.7729FX 1240 W
14x418.621.9823FX 1440 W
19x421.324.71069FX 1940 W
24x423.727.11297FX 2440 W
30x426.329.91578FX 3040 W
37x429.433.21935FX 3740 W