Marlew

series CCTSST

Wires 0.9 to 1.4mm
HDPE/LSZH
Up to 28 quads
FR < 0.3

For low and high frequency electrical signals transmission, for the transmission of electrical current in a low tension and intensity regime, for vocal communications. Used in underground train operations and for passenger access in underground stations. Installed in trays, cable ladders, in direct open air or indoors, directly buried or buried in a trench or in ducts.

Features

  • Temperature ratings: 70°C (Operating)

  • Construction requirements: As per ADIF ET 03.365.052.4

  • Conductor requirements: As per UNE 21011-2 – IRAM NM 280

  • Conductor: Single annealed electrolytic copper wire

  • Insulation: High density polyethylene (HDPE)

  • Assembly: 4 conductors twisted in a compacted quad. Diagonally opposing conductors make the pair

  • Lay length: Lower than 150mm

  • Bedding: LSZH-HFFR

  • Shield: Copper tape with the correct thickness and overlap to comply with reduction factor lower than 0.3 (FR <0.3)

  • Separation inner sheath: LSZH-HFFR

  • Armour: Double galvanized steel helical tape

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant), fire-retardant sunlight and oils resistant

  • Fire requirements: As per IEC 60332-3-24

  • Standard for halogen absence and corrosive gases: As per IEC 60754-1/2

  • Smoke transparency requirements: As per IEC 61034-1/2

  • Toxicity standard: As per NES 713 – CEI 20.37

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV Resistance)

  • Water behaviour requirements: Suitable AD7 (Occasional water submersion)

Electromagnetic interference protection

Electromagnetic interference protection

Fire-retardant

Fire-retardant

Halogen free

Halogen free

Low smoke

Low smoke

Antirodent protection

Antirodent protection

Underground trains

Underground trains

Identification

Standard
Sheath Conductors
Multi-quadET ADIF

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS, DIMENSIONS & WEIGHT

Number of quads Wire diameter Electrical resistance at 20ºC in C.C. Mutual capacitance in C.A. at 1000Hz y 20°C Diameter below shield Diameter under armour External diameter Weight Code Mat Number
Medium value Individual maximum Medium value Individual maximum
mm Ohm/km Ohm/km nF/km nF/km mm mm mm kg/km
10,927.5+/-129--458,714,219,26861X 0.9mm CCTSST - FR 0.3845000710
313,719,224,29443X 0.9mm CCTSST - FR 0.3845000720
516,722,227,211485X 0.9mm CCTSST - FR 0.3845000730
718,223,728,712737X 0.9mm CCTSST - FR 0.3845000740
1038+/323,228,733,7160110X 0.9mm CCTSST - FR 0.3845000750
1426,732,237,4196414X 0.9mm CCTSST - FR 0.3845000760
1929,535,240,4227719X 0.9mm CCTSST - FR 0.3845000770
11,411.2+/-0.511,9--489,214,719,77261X 1.4mm CCTSST - FR 0.3845000780
318,223,728,712543X 1.4mm CCTSST - FR 0.3845000790
522,728,233,216255X 1.4mm CCTSST - FR 0.3845000800
724,730,235,418767X 1.4mm CCTSST - FR 0.3845000810
1041+/-431,537,242,4256010X 1.4mm CCTSST - FR 0.3845000820
1435,541,446,6311114X 1.4mm CCTSST - FR 0.3845000830
1940,546,652,2388219X 1.4mm CCTSST - FR 0.3845000840
2547,553,859,4465825X 1.4mm CCTSST - FR 0.3845000850
2850,556,862,4508828X 1.4mm CCTSST - FR 0.3845000860