Marlew

series G-GC-L

EPR/TPU
2000 Volt
Extra-Heavy Duty
Cu 8AWG up to 500MCM

In oil fields it is used for feeding mobile drilling equipment, and in general for mobile outdoor installations with vertical and horizontal movement. It can withstand, while fixed or in movement, all types of efforts: traction, torsion, and flexion; caused by standard cable winding equipment. It counts with plastic materials which provide suitable protection against chemical products, harsh environment, tear and impacts. Additionally, these materials do not release halogen gases in the event of a fire. Suitable for applications where grounding conductors (G) and ground check conductors (GC) are needed This type of cable is required for extra-heavy duty industrial use. They are portable, reinforced power cables for use in mining developments for heavy mobile equipment such as tow cables, shovels, drills and power feeders.

Features

  • Maximum operating temperature: 90°C for fixed installation / 60°C for mobile use and occasional bending

  • Minimum ambient temperature: -40°C in fixed installation / -25°C for occasional bending

  • Rated voltage: 2000 Volt CA

  • Construction standard: ICEA S 75-381

  • Conductors standard: ASTM B 172/174

  • Conductor: Annealed electrolytic copper in flexible formation

  • Separator: Helical tape between conductor and insulation

  • Isolation: EPR

  • Cable formation: 3F (Phase) + 2G (Ground) + 1GC (Ground Check) Special tapes are applied to the group of conductors to ensure good circularity and allow slight slipping with respect to the cover when the cable is used

  • Sheat: Double polyurethane protection resistant to UV rays, hydrocarbons and chemicals in general with internal textile braid reinforcement to achieve greater mechanical integrity

  • Fire standard: UL 2556 (FT1)

  • Weathering standard: UL 2556 (rayos UV)

  • Hydrocarbon resistance standard: UIC 895 OR (oil, gas oil and fuel oil) / UL 13 (oil) / UL 83 (Fuel C: toluene and isoctane)

Flame retardant

Flame retardant

Tear and impacts

Tear and impacts

Halogen free

Halogen free

Flexible stranded conductors

Flexible stranded conductors

Harsh environment

Harsh environment

Identification

Flexible armored
Sheat
Conductors
Ground conductorSIN AISLAR
Ground check conductors

Instalation

Constructive variants

The information supplied corresponds to the standard version; upon request these cables can be supplied with another color cover.

ELECTRICAL, DIMENSIONAL AND WEIGHT CHARACTERISTICS

Phase conductor gauge (AWG/MCM) Protective conductor gauge (AWG) Check conductor gauge (AWG) Electrical resistance in DC at 20°C (*) Admissible intensity in air (**) External diameter Weight approx. Radio de curvatura Tensile stress Marlew Code
3x 2x 1x ohm/km Amper mm kg/km mm daN
810102.305924.6805148204G-GC-L-2kV 3x8+2G10+GC10
610101.447926.71012160278G-GC-L-2kV 3x6+2G10+GC10
48100.90610430.21415181427G-GC-L-2kV 3x4+2G8+GC10
38100.72012031.81606191510G-GC-L-2kV 3x3+2G8+GC10
27100.572138341882204636G-GC-L-2kV 3x2+2G7+GC10
1680.45116138.42388230811G-GC-L-2kV 3x1+2G6+GC8
1/0580.36218641.929342511012G-GC-L-2kV 3x1/0+2G5+GC8
2/0480.28721544.535052671264G-GC-L-2kV 3x2/0+2G4+GC8
3/0380.2282494842372881584G-GC-L-2kV 3x3/0+2G3+GC8
4/0280.18128751.851093111983G-GC-L-2kV 3x4/0+2G2+GC8
250280.15432060.761603642283G-GC-L-2kV 3x250+2G2+GC8
300180.1293576571553902746G-GC-L-2kV 3x300+2G1+GC8
3501/080.11039468.182374093232G-GC-L-2kV 3x350+2G1/0+GC8
4001/080.09643071.690374303622G-GC-L-2kV 3x400+2G1/0+GC8
4502/080.08646074.7102314484136G-GC-L-2kV 3x450+2G2/0+GC8
5002/080.07748777108294624511G-GC-L-2kV 3x500+2G2/0+GC8

(*) The electrical resistance reported corresponds only to the phase conductors. (**)Table H-1 of ICEA S 75-381 standard, maximum service temperature at 90ºC and ambient temperature of 40ºC